MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7863/jum.2005.24.12.1685

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2005

Tomographic ultrasound imaging of the fetal heart: a new technique for identifying normal and abnormal cardiac anatomy.

Devore Greggory R, Polanko Bardo

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

In 2003 and 2004, the American College of Radiology, the American Institute of Ultrasound in Medicine, and the American College of Obstetricians and Gynecologists published guidelines for the standard ultrasound examination of the fetus. Each group recommended that the outflow tracts of the fetal heart be examined if technically feasible. One method to accomplish this task is to perform a free-hand sweep of the transducer beam directed in a transverse plane from the 4-chamber view to the fetal neck. One problem with this approach is that the examiner may not direct the beam transversely and, therefore, may not accurately identify the outflow tract anatomy.

METHODS

A new technology, tomographic ultrasound imaging (TUI), allows the examiner to obtain a volume data set that simultaneously displays multiple images at specific distances from the 4-chamber view. This study examined TUI technology for identifying normal and abnormal fetal cardiac anatomy with the use of either static or spatiotemporal image correlation volume data sets.

RESULTS

The 4 views used in the screening examination of the outflow tracts of the fetal heart (4-chamber, 5-chamber, 3-vessel, and tracheal views) could be identified with the use of TUI technology in fetuses between 13 and 40 weeks' gestation. Examples of fetuses with abnormal cardiac anatomy of the outflow tracts (tetralogy of Fallot, transposition of the great vessels, and pulmonary stenosis) all showed abnormal anatomy on TUI.

CONCLUSIONS

Tomographic ultrasound imaging technology enables the fetal examiner to evaluate the 4-chamber view and the outflow tracts in a systematic manner to identify normal and abnormal cardiac anatomy.

Для цитирования: Devore Greggory R, Polanko Bardo. Tomographic ultrasound imaging of the fetal heart: a new technique for identifying normal and abnormal cardiac anatomy.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2005. DOI: 10.7863/jum.2005.24.12.1685.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.