Third-degree full-thickness burns as a complication of cervical radiofrequency ablation.

Tieppo Francio Vinicius, Barndt Brandon, Eubanks James, Smith McCasey

Клинический случайСтатьяПеревод в очереди

Аннотация

A 46-year-old woman underwent a cervical radiofrequency ablation (RFA) for chronic neck pain. Following the procedure, two areas surrounding the grounding pad in the lumbar region developed full thickness third-degree burns. Burn injuries following cervical RFA are rarely reported and are most often associated with cardiac and solid tumour RFA. Only one other case has been reported in literature with a similar outcome following a thoracic facet RFA. In our case, the lesion was directly from the ground pad and not from the radiofrequency electrode, which is more often the culprit. This is the first case reported in the literature of a full-thickness skin burn from a cervical RFA. Physicians should be aware of the potential for severe burns around the RF probe and ground pad as sequelae of RFA, and we caution the use of sedation during the procedure, as patients will unlikely be able to report any unusual sensation.

Для цитирования: Tieppo Francio Vinicius, Barndt Brandon, Eubanks James, Smith McCasey. Third-degree full-thickness burns as a complication of cervical radiofrequency ablation.. BMJ case reports. 2021. DOI: 10.1136/bcr-2021-245113.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.