DOI 10.1093/jalm/jfaa032

Медицинская библиотека · The journal of applied laboratory medicine · 2020

Comparison of Oral Fluid and Urine for Detection of Cocaine Abuse Using Liquid Chromatography with Tandem Mass Spectrometry.

Melanson Stacy E F, Petrides Athena K, Khaliq Tahira, Griggs David A, Flood James G

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Requests for urine (UR) and oral fluid (OF) drug testing at our institutions are increasing. However, few studies have assessed the accuracy of each matrix using paired specimens and LC-MS/MS. We compared OF and UR for detection of cocaine (COC) abuse in addiction medicine-psychiatry (AMP) clinics.

METHODS

We measured COC and benzoylecgonine (BZE) in OF (limit of detection (LOD) 2.0 µg/L) and BZE in UR (LOD 5 µg/L) by LC-MS/MS in 258 paired samples, and compared the two matrices when higher UR cutoffs of 25, 50, and 150 µg/L were employed.

RESULTS

UR detected more COC abuse than OF at the LOD (5 µg/L). BZE was detected in 63 UR specimens and COC and/or BZE in 40 OF specimens (29 OF+UR+, 11 OF+UR-, 34 OF-UR+). UR creatinine was lower in OF+UR- specimens. COC and BZE were detected in 88% (35/40) and 75% (30/40) of OF specimens, respectively. OF was equivalent to UR at detecting COC abuse using a 25 µg/L cutoff, and detected more COC abuse than UR using 50 and 150 µg/L cutoffs. The ratio of OF COC/BZE increased with decreasing UR BZE concentrations.

CONCLUSIONS

We demonstrate that OF detects more COC abuse in an AMP setting when UR BZE cutoffs ≥ 50 µg/L are utilized, and that UR creatinine concentrations are significantly lower in specimens positive for COC and/or BZE in OF and negative for BZE in UR. The presence of only COC in OF and low concentrations of UR BZE likely indicates remote use of COC.

Для цитирования: Melanson Stacy E F, Petrides Athena K, Khaliq Tahira, Griggs David A, Flood James G. Comparison of Oral Fluid and Urine for Detection of Cocaine Abuse Using Liquid Chromatography with Tandem Mass Spectrometry.. The journal of applied laboratory medicine. 2020. DOI: 10.1093/jalm/jfaa032.