MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ajo.12391

Медицинская библиотека · The Australian & New Zealand journal of obstetrics & gynaecology · 2015

A prospective pilot study in assessing the accuracy of ultrasound estimated fetal weight prior to delivery.

Sekar Renuka, Khatun Mohsina, Barrett Helen L, Duncombe Gregory

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Perinatal mortality and morbidity related to growth restriction and macrosomia are predicted by birthweight. Estimated fetal weight is a surrogate measure for neonatal weight, and accurate measurement of this is central to providing counselling and managing preterm birth.

AIMS: To assess the accuracy of estimated fetal weight (EFW) measured by two sonographers within 1 week of delivery using Hadlock formula.

MATERIALS AND

METHODS

Two sonographers independently scanned 150 women with singleton pregnancies, who were booked for elective delivery. The sonographers measured four biometric measurements in estimating fetal weight. The accuracy of EFW compared to the birthweight was examined. We also assessed the sensitivity and specificity for diagnosis of small-for-gestational age (SGA) and large-for-gestational age (LGA) according to the EFW.

RESULTS

Estimated fetal weight was similar to actual birthweight, with a mean percentage difference (SD) of 1.4(7.0) (P = 0.44). The reliability coefficient of EFW compared to actual birthweight was 0.97 (95% CI (0.96, 0.98)). There was no significant difference between the sonographers for EFWs and among the sonographers from the ultrasound scan to delivery interval. The sensitivity and specificity for detection of SGA and LGA were 93.3% and 99.3%, 60% and 95.6%, respectively.

CONCLUSIONS

There is high reproducibility with minimum discrepancy from actual birthweight among sonographers 1 week prior to delivery using Hadlock formula with better prediction of SGA neonates.

Для цитирования: Sekar Renuka, Khatun Mohsina, Barrett Helen L, Duncombe Gregory. A prospective pilot study in assessing the accuracy of ultrasound estimated fetal weight prior to delivery.. The Australian & New Zealand journal of obstetrics & gynaecology. 2015. DOI: 10.1111/ajo.12391.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.