MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/sleep/33.5.643

Медицинская библиотека · Sleep · 2010

Heritability of abnormalities in cardiopulmonary coupling in sleep apnea: use of an electrocardiogram-based technique.

Ibrahim Lamia H, Jacono Frank J, Patel Sanjay R, Thomas Robert J, Larkin Emma K, Mietus Joseph E, Peng Chung-Kang, Goldberger Ary L, Redline Susan

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

RATIONALE: Studies of the genetics of obstructive sleep apnea may be facilitated by identifying intermediate traits with high heritability that quantify etiological pathways, such as those related to respiratory control. Electrocardiogram (ECG)-based sleep spectrograms, measuring the coupling between respiratory modulation of ECG QRS-wave amplitude and heart rate variability, may provide measures of sleep state and ventilatory dynamics during sleep. We evaluated the familial aggregation of distinctive spectrographic biomarkers of unstable sleep, related to elevated-low frequency cardiopulmonary coupling (e-LFC), to assess their utility in genetic studies.

METHODS

622 participants from 137 families from the Cleveland Family Study underwent standardized polysomnography (PSG). From the ECG signal on the PSG, the interbeat interval time series and the corresponding ECG-derived respiratory signal were extracted, and the low frequency (0.01-0.1 Hz) component of their coupling was computed using a fully automated method. Narrow sense heritability of e-LFC was calculated using variance component methods.

RESULTS

A spectral marker of abnormal low frequency cardiopulmonary coupling (e-LFC) demonstrated moderate correlation with apnea hypopnea index (AHI; r = 0.35, P < 0.0001). The heritability estimate for e-LFC, after adjusting for age and sex was 0.32 (P < 10-5) and remained unchanged after additionally adjusting for body mass index or AHI. In biological relatives of those with sleep apnea, a related marker of e-LFC was more prevalent than in controls (P = 0.05).

CONCLUSIONS

Approximately 30% of the variability of e-LFC, measured from a continuous ECG during sleep, is explained by familial factors other than BMI. ECG-based spectrographic measures of cardiopulmonary coupling may provide novel phenotypes for characterizing subgroups of individuals with different propensities and genetic etiologies for sleep apnea or for other conditions associated with sleep fragmentation.

Для цитирования: Ibrahim Lamia H, Jacono Frank J, Patel Sanjay R, Thomas Robert J, Larkin Emma K, Mietus Joseph E, Peng Chung-Kang, Goldberger Ary L, Redline Susan. Heritability of abnormalities in cardiopulmonary coupling in sleep apnea: use of an electrocardiogram-based technique.. Sleep. 2010. DOI: 10.1093/sleep/33.5.643.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.