OBJECTIVE

To describe normal fetal cardiac and hemodynamic development in normal early first trimester pregnancies.

MATERIALS AND

METHODS

Eighty-eight women with singleton, uncomplicated pregnancies were prospectively studied with transvaginal ultrasound, pulsed and color Doppler. Heart diameter, heart rate, and inflow and outflow waveforms with valve signals were documented. The proportion of the cardiac cycle of isovolumetric relaxation time (IRT%) and isovolumetric contraction time (ICT%) as well as Tei index were calculated.

RESULTS

Ninety-one percent of studies were successful. Heart diameter and the fetal heart rate showed a positive correlation with increasing gestational age: R = 0.80 (p < 0.000001), R = 0.76 (p < 0.000001), respectively. Mean heart diameter at 6 weeks was 1.28 +/- 0.26 mm and mean fetal heart rate was 117 +/- 6 bpm compared to 3.88 +/- 0.54 mm and 171 +/- 6 bpm at 10 weeks. The inflow waveform was monophasic (atrial contraction) in all cases from 6 to 9 weeks. Eight pregnancies (9%) miscarried between 6 and 12 weeks of gestation and the heart exams were characterized by increased IRT% compared with the survivors. In survivors, IRT% decreased between 7 and 8 weeks, from 32.9 +/- 10.7% to 20.8 +/- 5.7% (p < 0.0001). ICT% decreased from 18.6 +/- 4.4% of the cardiac cycle at 8 weeks to 12.6 +/- 4.4% at 9 weeks (p < 0.0008) (after heart development period).

CONCLUSIONS

Doppler examination of the fetal cardiac function is possible after 5 weeks of gestation. After 8 weeks of gestation, the fetal heart is morphologically mature but has not yet achieved effective myocardial compliance. The embryonic human heart is dependent on the atrial contraction for ventricular filling throughout the period of cardiac development. Non-survivors manifest myocardial dysfunction.

Для цитирования: Włoch A, Rozmus-Warcholinska W, Czuba B, Borowski D, Włoch S, Cnota W, Sodowski K, Szaflik K, Huhta J C. Doppler study of the embryonic heart in normal pregnant women.. The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians. 2007. DOI: 10.1080/14767050701434747.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.