Assessing the Validity and Reliability of the PNOE¯ for Measuring Cardiometabolic Outcomes During Walking Exercise.

Kwok Manny M Y, Ng Shamay S M, Myers Jonathan, So Billy C L

СтатьяПеревод в очереди

Аннотация

Background

The accuracy of measurement of cardiometabolic outcomes in terms of gaseous exchange and energy expenditure of individuals is crucial. The objective of this study was to compare the validity and reliability of the PNOE¯ in measuring cardiometabolic outcomes from the respiratory gaseous exchange of healthy individuals during treadmill walking exercise.

Methods

A total of 21 healthy subjects (15 male and 6 female) aged 22.76 ± 3.85 years took part in this study. Oxygen uptake (VO2), carbon dioxide production (VCO2), respiratory exchange ratio (RER), metabolic equivalents (METs), tidal volume (VT), and energy expenditure (EE) were measured using the PNOE¯ and COSMED K5 portable systems during a twenty-eight-minute, four-stage incremental protocol, where speed increased from 1.7 mph to 4.2 mph with a 2% incline on a treadmill. Test-retest reliability was tested on separate days with trail repetition. Validity was evaluated by Bland-Altman plots, intraclass correlation coefficients (ICCs) and mean percentage difference.

Results

ICCs showed that VCO2 was in the good range (0.75-0.90). The ICC of the RER from stages 1 to 3 of the incremental protocol and the VT from stages 2 to 4 of the incremental protocol showed good to excellent reliability. No clear trend was seen for VO2, VCO2, and EE datapoints with variations in speed. Pearson's correlation coefficients were moderately high (r = 0.60-0.79) between VO2, VCO2, RER, METs, VT, and EE measured by the PNOE¯ and K5 systems. All subjects, except for a few cases in VT, were within the upper and lower 95% confidence intervals of the acceptable range of the Bland-Altman plots.

Conclusions

The PNOE¯ system is a valid and reliable measure of cardiometabolic outcomes and is comparable to the COSMED K5 system.

Для цитирования: Kwok Manny M Y, Ng Shamay S M, Myers Jonathan, So Billy C L. Assessing the Validity and Reliability of the PNOE¯ for Measuring Cardiometabolic Outcomes During Walking Exercise.. Journal of functional morphology and kinesiology. 2025. DOI: 10.3390/jfmk10020159.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.