MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1373/clinchem.2011.170290

Медицинская библиотека · Clinical chemistry · 2012

Nucleic acid detection immunoassay for prostate-specific antigen based on immuno-PCR methodology.

McDermed Jonathan E, Sanders Ron, Fait Stephen, Klem Robert E, Sarno Mark J, Adams Thomas H, Diamandis Eleftherios P

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Serum prostate-specific antigen (PSA) concentrations after radical prostatectomy typically become undetectable with the use of current immunometric assay methods. Despite modern surgical techniques, 15%-30% of prostate cancer patients undergoing radical prostatectomy develop a biochemical recurrence during follow-up. Unfortunately, poor analytical sensitivity of standard PSA assays delays biochemical recurrence detection, and because of day-to-day assay imprecision ultrasensitive PSA assays cannot assess PSA kinetics. We developed an immuno-PCR assay for total PSA that has a limit of quantification >10 times lower than current ultrasensitive assays.

METHODS

The 2-site immunometric assay for total PSA employed 2 monoclonal antibodies, one conjugated to a double-stranded DNA label and the other bound to paramagnetic microparticles. After several washing steps, quantification cycles were determined and values were converted to PSA concentrations. We characterized analytical performance and compared accuracy with a commercially available total PSA assay.

RESULTS

The limit of quantification was 0.65 ng/L and the assay was linear in the range of 0.25-152.0 ng/L. Total imprecision estimates at PSA concentrations of 3.8, 24.1, and 69.1 ng/L were <15.2%, <9.4%, and <10.6%, respectively. Recovery of supplemented PSA ranged from 87.5% to 119.2% (mean 100.3%). Dilution recovery ranged from 96.4% to 115.3% (mean 102.3%). There was no high-dose hook effect up to 50 000 ng/L of PSA. Comparison with the commercial PSA assay showed a regression slope of 1.06 and a correlation coefficient of 0.996.

CONCLUSIONS

The analytical characteristics of the assay support the use of this assay for the accurate and precise measurement of serum PSA, even at sub-nanogram-per-liter concentrations.

Для цитирования: McDermed Jonathan E, Sanders Ron, Fait Stephen, Klem Robert E, Sarno Mark J, Adams Thomas H, Diamandis Eleftherios P. Nucleic acid detection immunoassay for prostate-specific antigen based on immuno-PCR methodology.. Clinical chemistry. 2012. DOI: 10.1373/clinchem.2011.170290.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.