MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/02713683.2011.639124

Медицинская библиотека · Current eye research · 2012

Serum levels and H/L gene polymorphism of mannose-binding lectin in primary open angle glaucoma.

Dursun Ozer, Yilmaz Ayça, Ayaz Lokman, Tamer Lülüfer

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To analyze the serum levels and H/L gene polymorphisms of mannose-binding lectin-2 (MBL-2) in primary open angle glaucoma (POAG) cases and control subjects to investigate whether MBL-2 has a possible role in the development and pathogenesis of POAG.

MATERIALS AND

METHODS

In 45 POAG cases and age and sex-matched 45 healthy controls, Elisa Kit was used to determine serum levels of MBL-2. The genomic DNA of patient and control groups was extracted from whole blood using High Pure PCR template preparation kit. Genotyping of MBL-2 polymorphisms were detected by using a MBL-2 mutation detection kit in real-time PCR. Chi-square or Fisher's Exact Tests were used to evaluate the distribution of MBL-2 H/L genotypes among patients and control subjects. Associations between the H/L genotype and POAG risk were analyzed by using binary logistic regression. The serum MBL-2 levels of both groups were compared with Independent Sample t-test.

RESULTS

Mean MBL-2 serum levels in the patient group (21.30 ± 4.97 µg/mL) was significantly higher than the control group (17.48 ± 3.66 µg/mL), (p < 0.001). The distribution of alleles in the patient group was 28.9% for LL, 44.4% for HL, 26.7% for HH and in controls was 33.3% for LL, 37.8% for HL, 28.3% for HH. According to genotype ratios, the two groups were not different from each other.

CONCLUSIONS

Our findings may suggest an association between high serum MBL-2 levels and POAG, but H/L gene polymorphism of MBL-2 seems not to be associated with POAG.

Для цитирования: Dursun Ozer, Yilmaz Ayça, Ayaz Lokman, Tamer Lülüfer. Serum levels and H/L gene polymorphism of mannose-binding lectin in primary open angle glaucoma.. Current eye research. 2012. DOI: 10.3109/02713683.2011.639124.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.