DOI 10.1016/j.clinbiochem.2023.110614
Factors influencing creatine kinase-MM concentrations in newborns and implications for newborn screening for Duchenne muscular dystrophy.
Аннотация
INTRODUCTION
Newborn screening for Duchenne muscular dystrophy can be performed via a first-tier creatine kinase-MM measurement followed by reflex testing to second-tier molecular analysis of the DMD gene. In order to establish appropriate cut-offs for the creatine kinase-MM screen, factors that influence creatine kinase-MM in newborns were investigated.
MATERIALS AND
METHODS
Creatine kinase-MM data from a consented pilot study in New York State were collected over a two-year period and combined with de-identified validation data and analyzed. Univariate analysis and multiple linear regression analysis were performed.
RESULTS
The analysis indicated that age of newborn at specimen collection, gestational age and birth weight were significant influencers of CK-MM levels in newborns. In addition, to a lesser extent, sex, race/ethnicity and seasonal temperature also affect CK-MM levels in newborns.
CONCLUSIONS
To reduce false positive and false negative cases, newborn screening programs should be cognizant of factors that influence CK-MM when determining cut-offs for the assay. Variability based on age at specimen collection and birth weight are primarily observed within the first week of life. Therefore, particularly during this time period, multi-tiered cut-offs based on age of collection and lower cut-offs for premature and low birth weight babies are recommended. Other cut-off determinants may include sex, race/ethnicity and seasonal temperature.