OBJECTIVE

To evaluate the effectiveness of high-frequency oscillatory ventilation (HFOV) in pediatric patients with acute respiratory failure, failing conventional ventilation.

DESIGN

A prospective, clinical study.

SETTING

Tertiary care pediatric intensive care unit.

PATIENTS: Twenty pediatric patients (ages 12 days to 5 yrs) with acute respiratory failure (pneumonia, 14; sepsis with acute respiratory distress syndrome, 3; pulmonary edema as a complication of upper airway obstruction, 2; salicylate intoxication with acute respiratory distress syndrome, 1), failing conventional ventilation (median alveolar-arterial oxygen difference [P(A-a)O2] 578 [489-624] torr, median oxygenation index 26 [21-32].

INTERVENTIONS: HFOV was instituted after a median length of conventional ventilation of 15.5 (3.3-43.5) hrs.

MEASUREMENTS AND MAIN

RESULTS

Ventilator settings, arterial blood gases, oxygenation index, and P(A-a)O2 were recorded before HFOV (0 hrs) and at predetermined intervals during HFOV and compared using the one-way Friedman rank-sum procedure and a two-tailed Wilcoxon matched-pairs test. Initiation of HFOV caused a significant decrease in FiO2 at 1 hr that continued to 24 hrs (p <or= .04). In all patients, target ventilation was achieved, and 19 had improved oxygenation. After 1 hr, PaCO2 significantly decreased (p = .002) and remained within the target range thereafter. There were significant decreases in P(A-a)O2 and oxygenation index at 1 and 4 hrs, respectively, that were sustained up to 12 hrs (p <or= .04). No significant complications associated with HFOV were detected. Fifteen patients (75%) survived to hospital discharge. Only one patient died from respiratory failure.

CONCLUSIONS

In pediatric patients with acute respiratory failure, failing conventional ventilation, HFOV improves gas exchange in a rapid and sustained fashion. However, randomized controlled trials are needed to identify its benefits over conventional modes of mechanical ventilation.

Для цитирования: Ben Jaballah Nejla, Khaldi Ammar, Mnif Khaled, Bouziri Asma, Belhadj Sarra, Hamdi Asma, Kchaou Wassim. High-frequency oscillatory ventilation in pediatric patients with acute respiratory failure.. Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies. 2006. DOI: 10.1097/01.pcc.0000227108.38119.2e.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.