DOI 10.1111/j.1540-8183.2005.00043.x

Медицинская библиотека · Journal of interventional cardiology · 2005

Transcatheter device closure of interatrial septal defects in patients with hypoxia.

Ilkhanoff Leonard, Naidu Srihari S, Rohatgi Sameer, Ross Mitchell J, Silvestry Frank E, Herrmann Howard C

СтатьяПеревод в очереди

Аннотация

BACKGROUND

There has been growing interest in transcatheter closure of interatrial septal defects (IASDs) for a variety of indications, but reports are limited in patients with hypoxia from right-to-left shunting.

METHODS

Between August 2000 and October 2004, 181 patients were referred to our institution for elective closure of a patent foramen ovale (PFO) or atrial septal defect (ASD). Among these patients, 10 (5.5%) underwent closure for hypoxia due to persistent or intermittent right-to-left shunting. Clinical evaluation, including echocardiography with color Doppler and agitated saline, was performed in all patients to determine the degree of right-to-left shunting. Defects were closed with Amplatzer (n = 4) or Cardioseal (n = 6) devices, under transesophageal (TEE) or intracardiac echocardiography (ICE) guidance.

RESULTS

Mean age was 62.7 years (range: 31-88 years) with 70% female. Characteristics for closure included four patients with persistent hypoxia and six with intermittent hypoxia, including two with platypnea-orthodeoxia syndrome. All patients had echocardiography showing moderate (n = 6) or severe (n = 4) shunting. Patients had significant comorbidities, including chronic lung disease requiring supplemental oxygen (n = 5) and congestive heart failure (n = 2). TEE guidance was used in three patients, and ICE was performed in the remainder. Mean closure device diameter was 27 mm. Mean preprocedural arterial oxygen saturation of 86.7% improved to 95.9% immediately after closure, with color Doppler and agitated saline revealing the absence of (n = 5) or mild (n = 5) shunting. In-hospital major complications were limited to one patient with a transient ischemic attack after an initially unsuccessful closure attempt.

CONCLUSIONS

Percutaneous closure of IASDs in a heterogeneous group of patients with hypoxia can be safely and effectively performed. The procedure results in immediate arterial saturation improvement and reduced right-to-left shunting.

Для цитирования: Ilkhanoff Leonard, Naidu Srihari S, Rohatgi Sameer, Ross Mitchell J, Silvestry Frank E, Herrmann Howard C. Transcatheter device closure of interatrial septal defects in patients with hypoxia.. Journal of interventional cardiology. 2005. DOI: 10.1111/j.1540-8183.2005.00043.x.