Use of a silicone catheter with a Dacron cuff for dialysis short-term vascular access.
Аннотация
Polyurethane and Teflon subclavian vein catheters have been widely used for temporary vascular access for hemodialysis, but their use has been associated with a significant complication rate. A silicone dual-lumen catheter with a Dacron cuff placed in the internal jugular or subclavian vein was evaluated as a means of obtaining short-term vascular access. Sixty-two catheters in 54 patients provided a cumulative experience of 206 patient-months. Blood flow rates greater than or equal to 200 mL/min were achieved, with a mean recirculation of 2.1%. Catheter function was better with placement on the right side. Exit-site infections developed in nine patients, for a rate of 5.3 episodes per 100 patient-months; all resolved with antibiotics. Catheter-related bacteremia occurred in one patient, for a rate of 0.49 episodes per 100 patient-months, a rate much lower than rates reported for polyurethane and Teflon catheters. Clotting occurred in 24.5% of catheters, and thrombolytic therapy was always successful in restoring function. Because of the lower rate of complications, the silicone dual-lumen catheter with a Dacron cuff provides a safer alternative for short-term hemodialysis vascular access than the Teflon and polyurethane catheters.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.