MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.eupc.2003.09.006

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2004

Value of the implantable loop recorder for the management of patients with unexplained syncope.

Boersma Lucas, Mont Lluís, Sionis Alessandro, García Emilio, Brugada Josep

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIM: Recurrent syncope often remains unexplained despite extensive multidisciplinary screening. The implantable loop recorder (ILR) may be a tool to define the cardiac arrhythmias underlying syncope.

METHODS AND

RESULTS

The study population consisted of 43 consecutive patients with unexplained syncope who underwent extensive cardiological screening and were followed with an ILR. During follow-up, 5 patients had only presyncope, 4 had palpitations, and 15 had a true recurrence of syncope. In all patients with palpitations, 3 with presyncope, and 7 with a recurrence of syncope, the ILR excluded arrhythmias. In the patients with a true recurrence, 1 had symptomatic paroxysmal atrial fibrillation (PAF) treated with drugs, 1 had polymorphic ventricular tachycardia (VT) and received an implantable cardioverter defibrillator (ICD), and 7 had asystole and received a pacemaker. Two patients with presyncope received a pacemaker for Mobitz II block and PAF with brady-tachycardia syndrome. One asymptomatic patient received a pacemaker for significant nocturnal asystole recorded by ILR. Abnormalities in the cardiac screening were observed both in patients with and without syncope, but none of these had a predictive value.

CONCLUSION

The ILR is a valuable and effective tool to establish an arrhythmic cause for unexplained syncope. The results of head-up tilt testing (HUTT) and electrophysiological study (EPS) are neither sufficiently sensitive nor specific enough in this patient group.

Для цитирования: Boersma Lucas, Mont Lluís, Sionis Alessandro, García Emilio, Brugada Josep. Value of the implantable loop recorder for the management of patients with unexplained syncope.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2004. DOI: 10.1016/j.eupc.2003.09.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.