Chemosphere · 2023
Simultaneous biomonitoring of volatile organic compounds' metabolites in human urine samples using a novel in-syringe based fast urinary metabolites extraction (FaUMEx) technique coupled with UHPLC-MS/MS analysis.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gurrani Swapnil, Prakasham Karthikeyan, Huang Po-Chin, Wu Ming-Tsang, Wu Chia-Fang, Lin Yu-Chia, Tsai Bongee, Krishnan Anbarasu, Tsai Pei-Chien, Ponnusamy Vinoth Kumar
Аннотация
Assessing the impact of human exposure to environmental toxicants is often crucial to biomonitoring the exposed dose. In this work, we report a novel fast urinary metabolites extraction (FaUMEx) technique coupled with UHPLC-MS/MS analysis for the highly sensitive and simultaneous biomonitoring of the five major urinary metabolites (thiodiglycolic acid, s-phenylmercapturic acid, t,t-muconic acid, mandelic acid, and phenyl glyoxylic acid) of common volatile organic compounds' (VOCs) exposure (vinyl chloride, benzene, styrene, and ethylbenzene) in human. FaUMEx technique comprises of two-steps, liquid-liquid microextraction was performed first in an extraction syringe using 1 mL of methanol (pH 3) as an extraction solvent and then, the extractant was passed through a clean-up syringe (pre-packed-with various sorbents including 500 mg anhydrous MgSO4, 50 mg C18, and 50 mg SiO2) to obtain the high order of matrice clean-up and preconcentration efficiency. The developed method displayed excellent linearity, and the correlation coefficients were >0.998 for all the target metabolites with detection and quantification limits of 0.02-0.24 ng mL-1 and 0.05-0.72 ng mL-1, respectively. Furthermore, the matrix effects were < ±5%, and inter and intra-day precision were <9%. Moreover, the presented method was applied and validated to real sample analysis for biomonitoring of VOC's exposure levels. The results showed that the developed FaUMEx-UHPLC-MS/MS method is fast, simple, low-cost, low-solvent consumption, high sensitivity with good accuracy and precision for five targeted urinary VOCs' metabolites. Therefore, the presented dual-syringe mode FaUMEx strategy with UHPLC-MS/MS technique can be applied to biomonitoring of various urinary metabolites to assess human exposure to environmental toxicants.