MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aor.14885

Медицинская библиотека · Artificial organs · 2024

Anti-factor Xa and activated partial thromboplastin time strategies for unfractionated heparin dosing after HeartMate 3 left ventricular assist device implantation.

Feng Iris, Kurlansky Paul A, Powley Tanner R, Hynds Melissa A, Yang Christine G, Eisenberger Andrew, Hastie Jonathan M, Sutherland Lauren D, Yuzefpolskaya Melana, Colombo Paolo C, Sayer Gabriel T, Uriel Nir Y, Naka Yoshifumi, Takeda Koji

СтатьяПеревод в очереди

Аннотация

BACKGROUND

No clear guidelines exist for perioperative anticoagulation management after durable left ventricular assist device insertion. In this study, we sought to compare outcomes between anti-factor Xa (FXa) and activated partial thromboplastin time (aPTT) in monitoring unfractionated heparin (UFH) dosing after HeartMate 3 (HM3) insertion.

METHODS

This is a single-center retrospective review of patients who received UFH after HM3 insertion between 01/2020-12/2022. Post-operative UFH dose was titrated by aPTT goal 45-60 sec (n = 53) or FXa goal 0.1-0.2 U/mL (n = 59). Baseline differences between cohorts were balanced by inverse probability treatment weighting.

RESULTS

At baseline, unadjusted FXa patients were more likely to be white (47.5% vs. 35.8%, p < 0.001), INTERMACS 1-2 (69.5% vs. 47.2%, p = 0.013), have history of coronary artery disease (66.1% vs. 43.4%, p = 0.026), and lower eGFR (54.1 vs. 63.7 mL/min/1.73 m2, p = 0.029) compared to the aPTT group. After adjusting for several bleeding/thrombosis risk factors, 97.5% of FXa and 91.0% of aPTT patients reached therapeutic levels with comparable UFH duration and maximum dose. Moreover, in-hospital mortality (2.5% vs. 3.1%, p = 0.842), major bleeding events (4.2% vs. 9.2%, p = 0.360), and thromboembolic events (21.8% vs. 10.1%, p = 0.151) remained without significant differences between FXa and aPTT cohorts. There was a high degree of variability in FXa (r2 = 0.20) and aPTT (r2 = 0.22) values for any given UFH dose.

CONCLUSIONS

No differences in frequency of bleeding or thromboembolic events were observed in this study between FXa versus aPTT cohorts after HM3 implantation. More longitudinal studies are warranted to determine whether or not one assay is superior to the other.

Для цитирования: Feng Iris, Kurlansky Paul A, Powley Tanner R, Hynds Melissa A, Yang Christine G, Eisenberger Andrew, Hastie Jonathan M, Sutherland Lauren D, Yuzefpolskaya Melana, Colombo Paolo C, Sayer Gabriel T, Uriel Nir Y, Naka Yoshifumi, Takeda Koji. Anti-factor Xa and activated partial thromboplastin time strategies for unfractionated heparin dosing after HeartMate 3 left ventricular assist device implantation.. Artificial organs. 2024. DOI: 10.1111/aor.14885.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.