MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/978-1-0716-1476-1_18

Медицинская библиотека · Methods in molecular biology (Clifton, N.J.) · 2021

MYC Copy Number Detection in Clinical Samples Using a Digital DNA-Hybridization and Detection Method.

Ogbah Zighereda, Mancuso Francesco Mattia, Vivancos Ana

СтатьяПеревод в очереди

Аннотация

Clinical tumor specimens are routinely formalin-fixed and paraffin-embedded (FFPE) in Pathology departments worldwide. FFPE blocks are convenient, long-term stable, and easy to archive and manipulate. However, nucleic acids extracted from FFPE tissues generally show a high degree of fragmentation as well as chemical modifications, mainly due to the fixation process. Methods to determine copy number alterations (CNAs) from FFPE clinical samples have proven challenging, in the fact that they are low-plex, only able to profile single genes or gene clusters (such as in situ hybridization-based methods), and/or show a low degree of robustness with partially degraded samples (array-based, NGS-based) as well as being time-consuming, costly, and with limitations in resolution. The NanoString nCounter® System is a medium-plex, extremely FFPE-robust system, that overcomes several of the frequent issues when dealing with clinical samples. The technique is based on hybridization of molecular barcoded probes directly to FFPE-derived DNA, followed by single molecule imaging to detect hundreds of unique molecules in a single reaction without any amplification steps that might introduce undesired biases. Here we describe nCounter v2 Cancer Copy Number Assay, a robust and highly reproducible method for detecting the copy number status of 87 genes commonly amplified or deleted in cancer, including the MYC proto-oncogene.

Для цитирования: Ogbah Zighereda, Mancuso Francesco Mattia, Vivancos Ana. MYC Copy Number Detection in Clinical Samples Using a Digital DNA-Hybridization and Detection Method.. Methods in molecular biology (Clifton, N.J.). 2021. DOI: 10.1007/978-1-0716-1476-1_18.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.