MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00000542-198809000-00018

Медицинская библиотека · Anesthesiology · 1988

Preparation of anesthesia machines for patients susceptible to malignant hyperthermia.

Beebe J J, Sessler D I

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Malignant hyperthermia is a potentially lethal syndrome that can be triggered by inhaled anesthetics. Thus, it may be appropriate to utilize equipment that minimizes exposure of susceptible patients to inhaled anesthetics. The rate of release of anesthetic stored in anesthesia delivery systems is unknown. To determine residual anesthetic concentrations, the washout rates of halothane and isoflurane were compared, and the effects of a 1-l/min and a 10-l/min fresh gas flow were evaluated. Halothane concentrations were also measured in samples taken from the fresh gas outlet and the Y-piece of the circle system during four separate studies in which various components of the anesthesia system were replaced. In each study an Ohio Modulus anesthesia machine equipped with an Air-Shields ventilator was exposed to 2% halothane for 18 h. Anesthetic concentrations were determined by a gas chromatograph having a sensitivity of 0.1 ppm. Isoflurane washed out 3-4 times faster than halothane. Residual halothane concentration was approximately equal to tenfold greater when the fresh gas flow was 1 l/min rather than 10 l/min: 194 versus 19 ppm after 1 h of washout. Using a 10-l/min fresh gas flow, halothane concentrations in samples obtained from the Y-piece were similar with original or fresh soda lime but were more than tenfold lower after the fresh gas outlet hose and circle system were replaced (approximately equal to 50 ppm vs. approximately equal to 5 ppm after 5 min of washout).(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Beebe J J, Sessler D I. Preparation of anesthesia machines for patients susceptible to malignant hyperthermia.. Anesthesiology. 1988. DOI: 10.1097/00000542-198809000-00018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.