International archives of occupational and environmental health · 2021

Evaluation of a safe infusion device on reducing occupational exposure of nurses to antineoplastic drugs: a comparative prospective study. Contamoins-1.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Forges Fabien, Blanc Emeline, Raymond Bastien, Menguy Sandrine, Macé Agnès, Hugues Marion, Macron Corinne, Bouleftour Wafa, Tinquaut Fabien, Guitton Jérôme, Simoëns Xavier

Аннотация

PURPOSE: Despite the decreasing of environmental contamination throughout the anticancer drug circuit, the administration of chemotherapies remains at risk of occupational exposure for nurses. Many medical devices aim at securing administration, but none have been scientifically evaluated to verify the actual improvement.

METHODS: A monocentric comparative before/after study was carried out in an oncology day hospital to evaluate the efficacy of Safe Infusion Devices in reducing drug exposure compared to usual infusion practices. The rate of nurses' gloves contamination was estimated. To avoid false negatives and to ensure sampling reproducibility, each sample of gloves was contaminated with a drop of topotecan. Association between contamination and other variables was investigated using a multivariate logistic regression analysis.

RESULTS: The usual practice led to a rate of 58.3% of contaminated samples while Safe Infusion Devices to a rate of 15%: Safe Infusion Devices reduced the risk of gloves contamination by 85% in multivariate analysis (Odds ratio = 0.15; 95% confidence interval = 0.05-0.46; p < 0.001). Topotecan was identified in 100% of the samples. Only one case of cross-contamination has occurred.

CONCLUSION: Despite the current practice of using neutral solvent-purged infusers, the occupational exposure remains high for nurses and Safe Infusion Devices significantly reduced this risk of exposure. However, glove contamination is only a surrogate endpoint. The results confirmed that the disconnection of empty bags resulted in occupational exposure. Except a contamination due to the leakage of a bag, no cross-contamination was detected. Safe Infusion Devices were highly effective but did not completely eliminate exposure.