MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chemosphere.2021.129991

Медицинская библиотека · Chemosphere · 2021

Is high resolution a strict requirement for mass spectrometry-based cellular DNA adductomics?

Chang Yuan-Jhe, Cooke Marcus S, Chen Yet-Ran, Yang Shun-Fa, Li Pei-Shan, Hu Chiung-Wen, Chao Mu-Rong

СтатьяПеревод в очереди

Аннотация

Exposure to endogenous and exogenous factors can result in the formation of a wide variety of DNA adducts, and these may lead to gene mutations, thereby contributing to the development of cancer. DNA adductomics, a novel tool for exposomics, aims to detect the totality of DNA adducts. Liquid chromatography-high resolution mass spectrometry (LC-HRMS) is the state-of-the-art method for DNA adductomic analysis, although its high cost has limited widespread use. In this study, we compared the analytical performance between HRMS and the more popular/accessible triple-quadrupole MS (QqQ-MS). We initially developed and optimized a hybrid quadrupole-linear ion trap-orbitrap MS (Q-LIT-OT-MS) method, considering the detection of both purine and pyrimidine adducts. LC-Q-LIT-OT-MS and LC-QqQ-MS methods were compared by non-targeted screening of formaldehyde-induced DNA adducts. Using the results from Q-LIT-OT-MS as the gold standard, QqQ-MS successfully detected 12 out of 18 formaldehyde-induced DNA adducts/inter-strand crosslinks (ICLs). QqQ-MS however also produced nine false-positive results owing to the inherent instrumental mass resolution limits. To discriminate the false-positive results from the accurate ones, we firstly introduced a statistical analysis, partial least squares-discriminant analysis, which efficiently excluded the false signals. Six DNA adducts/ICLs were not detected by QqQ-MS, due to insufficient sensitivity. This could be overcome by employing a selected reaction monitoring scan mode with multiple injections. Overall, this study demonstrated that high resolution may not be a strict requirement for MS-based DNA adductomics. LC-QqQ-MS with statistical analysis, could also provide a comparable performance as HRMS for pre-screening purposes.

Для цитирования: Chang Yuan-Jhe, Cooke Marcus S, Chen Yet-Ran, Yang Shun-Fa, Li Pei-Shan, Hu Chiung-Wen, Chao Mu-Rong. Is high resolution a strict requirement for mass spectrometry-based cellular DNA adductomics?. Chemosphere. 2021. DOI: 10.1016/j.chemosphere.2021.129991.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.