MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.radonc.2023.109794

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2023

Clinical target volume delineation quality assurance for MRI-guided prostate radiotherapy using deep learning with uncertainty estimation.

Min Hang, Dowling Jason, Jameson Michael G, Cloak Kirrily, Faustino Joselle, Sidhom Mark, Martin Jarad, Cardoso Michael, Ebert Martin A, Haworth Annette, Chlap Phillip, de Leon Jeremiah, Berry Megan, Pryor David, Greer Peter, Vinod Shalini K, Holloway Lois

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Previous studies on automatic delineation quality assurance (QA) have mostly focused on CT-based planning. As MRI-guided radiotherapy is increasingly utilized in prostate cancer treatment, there is a need for more research on MRI-specific automatic QA. This work proposes a clinical target volume (CTV) delineation QA framework based on deep learning (DL) for MRI-guided prostate radiotherapy.

MATERIALS AND

METHODS

The proposed workflow utilized a 3D dropblock ResUnet++ (DB-ResUnet++) to generate multiple segmentation predictions via Monte Carlo dropout which were used to compute an average delineation and area of uncertainty. A logistic regression (LR) classifier was employed to classify the manual delineation as pass or discrepancy based on the spatial association between the manual delineation and the network's outputs. This approach was evaluated on a multicentre MRI-only prostate radiotherapy dataset and compared with our previously published QA framework based on AN-AG Unet.

RESULTS

The proposed framework achieved an area under the receiver operating curve (AUROC) of 0.92, a true positive rate (TPR) of 0.92 and a false positive rate of 0.09 with an average processing time per delineation of 1.3 min. Compared with our previous work using AN-AG Unet, this method generated fewer false positive detections at the same TPR with a much faster processing speed.

CONCLUSION

To the best of our knowledge, this is the first study to propose an automatic delineation QA tool using DL with uncertainty estimation for MRI-guided prostate radiotherapy, which can potentially be used for reviewing prostate CTV delineation in multicentre clinical trials.

Для цитирования: Min Hang, Dowling Jason, Jameson Michael G, Cloak Kirrily, Faustino Joselle, Sidhom Mark, Martin Jarad, Cardoso Michael, Ebert Martin A, Haworth Annette, Chlap Phillip, de Leon Jeremiah, Berry Megan, Pryor David, Greer Peter, Vinod Shalini K, Holloway Lois. Clinical target volume delineation quality assurance for MRI-guided prostate radiotherapy using deep learning with uncertainty estimation.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2023. DOI: 10.1016/j.radonc.2023.109794.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.