Combining conventional technique with fluoroscopy integration module in accessory pathway ablation.
Аннотация
INTRODUCTION
Accessory pathway (AP) ablation is a straightforward approach with high success rates, but the fluoroscopy time (FT) is significantly longer in conventional technique. Electroanatomical mapping systems (EMS), reduce the FT, but anatomical and activation mapping may prolong the procedure time (PT). The fluoroscopy integration module (FIM) uses prerecorded fluoroscopy images and allows ablation similar to conventional technique without creating an anatomical map. In this study, we investigated the effects of combining the FIM with traditional technique on PT, success, and radiation exposure.
METHODS
A total of 131 patients who had undergone AP ablation were included in our study. In 37 patients, right and left anterior oblique (RAO-LAO) images were acquired after catheter placement and integrated with the FIM. The ablation procedure was then similar to the conventional technique, but without the use of fluoroscopy. For the purpose of acceleration, anatomical and activation maps have not been created. Contact-force catheters were not used. 94 patients underwent conventional ablation using fluoroscopy only.
RESULTS
FIM into AP ablation procedures led to a significant reduction in radiation exposure, lowering FT from 7.4 to 2.8 min (p < .001) and dose-area product from 12.47 to 5.8 μGym² (p < .001). While the FIM group experienced a reasonable longer PT (69 vs. 50 min p < .001). FIM reduces FT regardless of operator experience and location of APs
CONCLUSION
Combining FIM integration with conventional AP ablation offers reduced radiation exposure without compromising success rates and complication.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.