MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2020.07.060

Медицинская библиотека · Journal of the American College of Cardiology · 2020

Gadobutrol-Enhanced Cardiac Magnetic Resonance Imaging for Detection of Coronary Artery Disease.

Arai Andrew E, Schulz-Menger Jeanette, Berman Daniel, Mahrholdt Heiko, Han Yuchi, Bandettini W Patricia, Gutberlet Matthias, Abraham Arun, Woodard Pamela K, Selvanayagam Joseph B, McCann Gerry P, Hamilton-Craig Christian, Schoepf U Joseph, San Tan Ru, Kramer Christopher M, Friedrich Matthias G, Haverstock Daniel, Liu Zheyu, Brueggenwerth Guenther, Bacher-Stier Claudia, Santiuste Marta, Pennell Dudley J, GadaCAD Investigators

Клиническое исследование III фазыСтатьяResearch Support, N.I.H., IntramuralПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Gadolinium-based contrast agents were not approved in the United States for detecting coronary artery disease (CAD) prior to the current studies.

OBJECTIVES

The purpose of this study was to determine the sensitivity and specificity of gadobutrol for detection of CAD by assessing myocardial perfusion and late gadolinium enhancement (LGE) imaging.

METHODS

Two international, single-vendor, phase 3 clinical trials of near identical design, "GadaCAD1" and "GadaCAD2," were performed. Cardiovascular magnetic resonance (CMR) included gadobutrol-enhanced first-pass vasodilator stress and rest perfusion followed by LGE imaging. CAD was defined by quantitative coronary angiography (QCA) but computed tomography coronary angiography could exclude significant CAD.

RESULTS

Because the design and results for GadaCAD1 (n = 376) and GadaCAD2 (n = 388) were very similar, results were summarized as a fixed-effect meta-analysis (n = 764). The prevalence of CAD was 27.8% defined by a ≥70% QCA stenosis. For detection of a ≥70% QCA stenosis, the sensitivity of CMR was 78.9%, specificity was 86.8%, and area under the curve was 0.871. The sensitivity and specificity for multivessel CAD was 87.4% and 73.0%. For detection of a 50% QCA stenosis, sensitivity was 64.6% and specificity was 86.6%. The optimal threshold for detecting CAD was a ≥67% QCA stenosis in GadaCAD1 and ≥63% QCA stenosis in GadaCAD2.

CONCLUSIONS

Vasodilator stress and rest myocardial perfusion CMR and LGE imaging had high diagnostic accuracy for CAD in 2 phase 3 clinical trials. These findings supported the U.S. Food and Drug Administration approval of gadobutrol-enhanced CMR (0.1 mmol/kg) to assess myocardial perfusion and LGE in adult patients with known or suspected CAD.

Для цитирования: Arai Andrew E, Schulz-Menger Jeanette, Berman Daniel, Mahrholdt Heiko, Han Yuchi, Bandettini W Patricia, Gutberlet Matthias, Abraham Arun, Woodard Pamela K, Selvanayagam Joseph B, McCann Gerry P, Hamilton-Craig Christian, Schoepf U Joseph, San Tan Ru, Kramer Christopher M, Friedrich Matthias G, Haverstock Daniel, Liu Zheyu, Brueggenwerth Guenther, Bacher-Stier Claudia, Santiuste Marta, Pennell Dudley J, GadaCAD Investigators. Gadobutrol-Enhanced Cardiac Magnetic Resonance Imaging for Detection of Coronary Artery Disease.. Journal of the American College of Cardiology. 2020. DOI: 10.1016/j.jacc.2020.07.060.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.