MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/iop.0b013e318223247d

Медицинская библиотека · Ophthalmic plastic and reconstructive surgery · 2012

Silicone spacer repair of medial rectus after iatrogenic orbit fracture.

Krakauer Mark, Aakalu Vinay K, Davis Patricia L, Ahmad Amjad Z

Клинический случайСтатьяПеревод в очереди

Аннотация

A 51-year-old woman underwent endoscopic nasal polypectomy and ethmoidectomy with accidental entry into the right orbit causing enophthalmos and transection of the medial rectus muscle (MR). The repair of a fracture and of a damaged MR is technically challenging, particularly when large portions of bone and muscle are missing. We report a rare case of repair of the bony defect with an implant and reattachment of the MR with a silicone retina band, through a combined transcaruncular and transconjunctival approach. Postoperatively, the patient had residual enophthalmos and strabismus; further surgical options are discussed.

Для цитирования: Krakauer Mark, Aakalu Vinay K, Davis Patricia L, Ahmad Amjad Z. Silicone spacer repair of medial rectus after iatrogenic orbit fracture.. Ophthalmic plastic and reconstructive surgery. 2012. DOI: 10.1097/iop.0b013e318223247d.