DOI 10.1016/j.eururo.2007.11.025
The inside-out trans-obturator sling: a novel surgical technique for the treatment of male urinary incontinence.
Аннотация
OBJECTIVES
To describe a new sling procedure for treating stress urinary incontinence (SUI) after radical prostatectomy (RP) and prospectively evaluate its short-term safety and efficacy.
METHODS
The sling technique uses specific instruments and a polypropylene mesh with two arms that are passed inside to outside through the obturator foramens, pulled for compressing the bulbar urethra upward, and tied to each other across the midline. Patients with detrusor overactivity were excluded. Baseline and follow-up evaluations included uroflowmetry and continence and quality of life (QoL) questionnaires. Cure was defined by no pad use and improvement by a number of pads/d <or=2 and reduced by at least 50%. Complications were recorded.
RESULTS
From April 2006 through February 2007, 20 consecutive patients suffering from post-RP SUI underwent the sling procedure using the same operative protocol. Preoperatively, 3 (15%), 11 (55%), and 6 (25%) patients were using 2, 3-5, and >5pads/d, respectively. The procedure was preceded by an endoscopic urethrotomy in four patients. No perioperative complication was noted; three patients required suprapubic catheterization. At 6 mo, nine (45%) patients were cured and eight others (40%) were improved (1pad/d). QoL was significantly enhanced and 80% of patients were moderately to completely satisfied with the procedure. Preoperative and postoperative maximum flow rate and postvoid residual values were not statistically different. No sling infection, urethra erosion, persistent pain, or neurologic complications were observed.
CONCLUSIONS
The inside-out trans-obturator sling procedure appears to be safe and efficient at short term. Further studies are warranted to determine long-term outcome.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.