MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/adma.202412701

Медицинская библиотека · Advanced materials (Deerfield Beach, Fla.) · 2024

Aggregation-Disruption-Induced Multi-Scale Mediating Strategy for Anticoagulation in Blood-Contacting Devices.

Pan Mingfei, Sun Zhaoyun, Zhang Yuhao, Chen Jiangwei, Zhao Ziqian, He Hongliang, Zeng Hongbo, Li Qingguo, Gu Ning

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Minimally invasive blood-contacting interventional devices are increasingly used to treat cardiovascular diseases. However, the risk of device-related thrombosis remains a significant concern, particularly the formation of cycling thrombi, which pose life-threatening risks. To better understand the interactions between these devices and blood, the initial stages of coagulation contact activation on extrinsic surfaces are investigated. Direct force measurements reveals that activated contact factors stimulate the intrinsic coagulation pathway and promote surface crosslinking of fibrin. Furthermore, fibrin aggregation is disrupted by surface-grafted inhibitors, as confirmed by ex vivo coagulation tests. An engineered serum protein with zwitterion grafts to resist the deposition of biological species such as fibrin, platelets, and red blood cells is also developed. Simultaneously, a protease inhibitor-based coacervate is incorporated into the coating to inhibit the intrinsic pathway effectively. The loaded coacervate can be released and reloaded through modulation of catechol-amine interactions, facilitating material regeneration. The strategy offers a novel multi-scale mediation strategy that simultaneously inhibits nanoscale coagulation factors and resists microscale thrombus aggregation, providing a long-term solution for anticoagulation in blood-contacting devices.

Для цитирования: Pan Mingfei, Sun Zhaoyun, Zhang Yuhao, Chen Jiangwei, Zhao Ziqian, He Hongliang, Zeng Hongbo, Li Qingguo, Gu Ning. Aggregation-Disruption-Induced Multi-Scale Mediating Strategy for Anticoagulation in Blood-Contacting Devices.. Advanced materials (Deerfield Beach, Fla.). 2024. DOI: 10.1002/adma.202412701.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.