MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/jes.2013.68

Медицинская библиотека · Journal of exposure science & environmental epidemiology · 2013

A novel system to generate WTC dust particles for inhalation exposures.

Vaughan Joshua M, Garrett Brittany J, Prophete Colette, Horton Lori, Sisco Maureen, Soukup Joleen M, Zelikoff Judith T, Ghio Andrew, Peltier Richard E, Asgharian Bahman, Chen Lung-Chi, Cohen Mitchell D

СтатьяПоддержка NIH: внешняя программаПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

First responders (FRs) present at Ground Zero within the critical first 72 h after the World Trade Center (WTC) collapse have progressively exhibited significant respiratory injury. The majority (>96%) of WTC dusts were >10 μm and no studies have examined potential health effects of this size fraction. This study sought to develop a system to generate and deliver supercoarse (10-53 μm) WTC particles to a rat model in a manner that mimicked FR exposure scenarios. A modified Fishing Line generator was integrated onto an intratracheal inhalation (ITIH) system that allowed for a bypassing of the nasal passages so as to mimic FR exposures. Dust concentrations were measured gravimetrically; particle size distribution was measured via elutriation. Results indicate that the system could produce dusts with 23 μm mass median aerodynamic diameter (MMAD) at levels up to ≥1200 mg/m(3). To validate system utility, F344 rats were exposed for 2 h to ≈100 mg WTC dust/m(3). Exposed rats had significantly increased lung weight and levels of select tracer metals 1 h after exposure. Using this system, it is now possible to conduct relevant inhalation exposures to determine adverse WTC dusts impacts on the respiratory system. Furthermore, this novel integrated Fishing Line-ITIH system could potentially be used in the analyses of a wide spectrum of other dusts/pollutants of sizes previously untested or delivered to the lungs in ways that did not reflect realistic exposure scenarios.

Для цитирования: Vaughan Joshua M, Garrett Brittany J, Prophete Colette, Horton Lori, Sisco Maureen, Soukup Joleen M, Zelikoff Judith T, Ghio Andrew, Peltier Richard E, Asgharian Bahman, Chen Lung-Chi, Cohen Mitchell D. A novel system to generate WTC dust particles for inhalation exposures.. Journal of exposure science & environmental epidemiology. 2013. DOI: 10.1038/jes.2013.68.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.