MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2011.12.036

Медицинская библиотека · Biosensors & bioelectronics · 2011

Detection of single-nucleotide polymorphisms with novel leaky surface acoustic wave biosensors, DNA ligation and enzymatic signal amplification.

Xu Qinghua, Chang Kai, Lu Weiping, Chen Wei, Ding Yi, Jia Shuangrong, Zhang Kejun, Li Fake, Shi Jianfeng, Cao Liang, Deng Shaoli, Chen Ming

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

This manuscript describes a new technique for detecting single-nucleotide polymorphisms (SNPs) by integrating a leaky surface acoustic wave (LSAW) biosensor, enzymatic DNA ligation and enzymatic signal amplification. In this technique, the DNA target is hybridized with a capture probe immobilized on the surface of a LSAW biosensor. Then, the hybridized sequence is ligated to biotinylated allele-specific detection probe using Taq DNA ligase. The ligation does not take place if there is a single-nucleotide mismatch between the target and the capture probe. The ligated detection probe is transformed into a streptavidin-horseradish peroxidase (SA-HRP) terminal group via a biotin-streptavidin complex. Then, the SA-HRP group catalyzes the polymerization of 3,3-diaminobenzidine (DAB) to form a surface precipitate, thus effectively increasing the sensitivity of detecting surface mass changes and allowing detection of SNPs. Optimal detection conditions were found to be: 0.3 mol/L sodium ion concentration in PBS, pH 7.6, capture probe concentration 0.5 μmol/L and target sequence concentration 1.0 μmol/L. The detection limit was found to be 1 × 10(-12)mol/L. Using this technique, we were able to detect a single-point mutation at nucleotide A2293G in Japanese encephalitis virus.

Для цитирования: Xu Qinghua, Chang Kai, Lu Weiping, Chen Wei, Ding Yi, Jia Shuangrong, Zhang Kejun, Li Fake, Shi Jianfeng, Cao Liang, Deng Shaoli, Chen Ming. Detection of single-nucleotide polymorphisms with novel leaky surface acoustic wave biosensors, DNA ligation and enzymatic signal amplification.. Biosensors & bioelectronics. 2011. DOI: 10.1016/j.bios.2011.12.036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.