MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/qshc.2007.024810

Медицинская библиотека · Quality & safety in health care · 2009

Patient safety on the otolaryngology service: the role of an established rapid response system.

Oliver C L, Devita M A, Dunwoody C J, Johnson J T, Sok J C, Simmons R L

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To study the medical emergencies occurring on a tertiary otolaryngology service identified using a rapid response system (RRS).

DESIGN

Retrospective chart review of RRS activations during 21 months.

SETTING

Specialised otolaryngology care unit within the University of Pittsburgh Medical Center Presbyterian/Montefiore Hospital, a tertiary, academic, teaching hospital in the USA.

INTERVENTION(S): None.

RESULTS

1171 unit admissions. Unit mortality was 5.1/1000 admissions. 53 patients were involved in 67 RRS activations (4/53 deaths). 32 of 67 events were due to respiratory derangements, most commonly pneumonia. 18 of 67 events were due to cardiovascular abnormalities, most commonly hypertension and myocardial infarction. 11 of 67 events were secondary to mental status changes, several of which were related to adverse drug events. 6 of 67 events were secondary to acute bleeding. 23 of 67 events occurred within 24 h of patient transfer/admission, 14 of those after operations. RRS activation was a marker for in-hospital death (RR 42.2, 95% CI 7.9 to 225.2) compared with that in patients not activating the RRS.

CONCLUSIONS

Although otolaryngology care units attempt to prevent adverse events, emergencies still occur. RRSs identify deteriorating otolaryngology patients who are at increased risk for mortality. RRSs are an efficient mechanism of intervention during a medical emergency. RRSs provide a convenient method of identifying medical/system errors and educational opportunities.

Для цитирования: Oliver C L, Devita M A, Dunwoody C J, Johnson J T, Sok J C, Simmons R L. Patient safety on the otolaryngology service: the role of an established rapid response system.. Quality & safety in health care. 2009. DOI: 10.1136/qshc.2007.024810.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.