Impact of Shaking EDTA, Citrate, or MgSO4 Tubes on Platelet Count Results.

Soulard Michel, Ketatni Hela, Visseaux Claire, Croix Pascale, Cohen Patrick

СтатьяПеревод в очереди

Аннотация

Background

In EDTA-induced pseudothrombopenia, citrate or MgSO4 are recommended for platelet counting. Pre-analytical conditions are poorly defined for tubes containing MgSO4 or citrate. In this study, we analyzed the impact of agitation of these tubes on platelet counts.

Methods

K2EDTA, citrate, and MgSO4 tubes from 70 patients were gently agitated on a wheel rotating at 20 rpm. Platelets were analyzed on the Sysmex XN analyzer at different times, and the percentage of platelet deviation from T0 was assessed and compared with the desirable bias of the EFLM.

Results

at 180 min in fluorescence, the relative variation of platelets after shaking is 1.17% for K2EDTA, -29.76% for citrate, and -33.18% for MgSO4, while for unshaken MgSO4 platelets the variation is -1.3%. The reduction in platelet numbers when citrate or MgSO4 tubes are shaken is linked to the appearance of platelet clusters.

Conclusions

agitation of MgSO4 and especially citrate tubes led to a decrease in platelet counts due to the formation of platelet aggregates; on the other hand, platelet counts on EDTA are virtually stable. During transport, we recommend putting sodium citrate and MgSO4 tubes in an upright position and avoiding shaking them to avoid giving an erroneous platelet result.

Для цитирования: Soulard Michel, Ketatni Hela, Visseaux Claire, Croix Pascale, Cohen Patrick. Impact of Shaking EDTA, Citrate, or MgSO4 Tubes on Platelet Count Results.. Journal of clinical medicine. 2024. DOI: 10.3390/jcm13185350.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.