m+Medelevator.RU
← Поиск публикаций
The American journal of cardiology · 2008

Comparison of angiographic and intravascular ultrasonic detection of myocardial bridging of the left anterior descending coronary artery.

Сравнительное исследованиеОценочное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tsujita Kenichi, Maehara Akiko, Mintz Gary S, Doi Hiroshi, Kubo Takashi, Castellanos Celia, Liu Jian, Yang Junqing, Oviedo Carlos, Franklin-Bond Theresa, Dasgupta Neil, Biro Sinan, Dani Lokesh, Dangas George D, Mehran Roxana, Kirtane Ajay J, Lansky Alexandra J, Kreps Edward M, Collins Michael B, Stone Gregg W, Moses Jeffrey W, Leon Martin B

Аннотация

The purpose of this study was to determine the incidence, location, and clinical features of myocardial bridging (MB) detected by intravascular ultrasound (IVUS) and to compare IVUS-detectable versus angiographically detectable MBs. IVUS images were analyzed in 331 consecutive patients with de novo coronary lesions located in the left anterior descending coronary artery (LAD). MB was defined as a segment of coronary artery having systolic compression and echocardiographically lucent muscle surrounding the artery (IVUS) or systolic milking (angiography). Although angiography detected MB in only 3% of patients (11 of 331), 75 MB segments (23%, 75 of 331, p <0.001) were identified by IVUS. Maximum plaque burden within the MB segment measured only 25 +/- 7%, and abnormal intimal thickness (defined as >or=0.5 mm) was not observed within the bridged segment of any patient with MB, although the study population had advanced atherosclerosis. Vessel and lumen areas in the MB segment were significantly smaller than those in adjacent proximal and even distal reference segments. Angiographically detectable MB was significantly longer, located more proximally in the LAD, and had more severe systolic compression by IVUS. Angiographically silent MB more often occurred in the presence of an adjacent proximal stenosis and lower left ventricular ejection fraction. In conclusion, IVUS may provide useful anatomic information for the accurate diagnosis of MBs that are largely angiographically silent. IVUS-detectable MBs were observed in approximately 1/4 of patients undergoing LAD imaging at our center.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты