Is 300 Seconds ACT Safe and Efficient during MiECC Procedures?

Bauer Adrian, Hausmann Harald, Schaarschmidt Jan, Szlapka Michal, Scharpenberg Martin, Eberle Thomas, Hasenkam J Michael

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

The recommended minimum activated clotting time (ACT) level for cardiopulmonary bypass (CPB) of 480 seconds originated from investigations with bubble oxygenators and uncoated extracorporeal circulation (ECC) systems. Modern minimal invasive ECC (MiECC) systems are completely closed circuits containing a membrane oxygenator and a tip-to-tip surface coating. We hypothesized that surface coating and the "closed-loop" design allow the MiECC to safely run with lower ACT levels and that an ACT level of 300 seconds can be safely applied without thromboembolic complications. The aim of this study was to investigate the potential risks during application of reduced heparin levels in patients undergoing coronary surgery.

METHODS

In this study, 68 patients undergoing coronary artery bypass grafting with MiECC were randomized to either the study group with an ACT target of 300 seconds or the control group with an ACT of 450 seconds. All other factors of MiECC remained unchanged.

RESULTS

The study group received significantly less heparin and protamine (heparin [international units] median [min-max], Red_AC: 32,800 [23,000-51,500] vs. Full_AC: 50,000 [35,000-65,000] p < 0.001; protamine [international units], Red_AC: 18,000 [10,000-35,000] vs. Full_AC: 30,000 [20,000-45,000] p < 0.001). The ACT in the study group was significantly lower at the start of MiECC (mean ± standard deviation: study group 400 ± 112 vs. control group 633 ± 177; p < 0.0001). Before termination of CPB the ACT levels were: study group 344 ± 60 versus control group 506 ± 80. In both groups, the values of the endogenous thrombin potential (ETP) decreased simultaneously. None of the study participants experienced thromboembolic complications.

CONCLUSION

Since no evidence of increased thrombin formation (ETP) was found from a laboratory standpoint, we concluded that the use of MiECC with a reduced anticoagulation strategy seems possible. This alternative anticoagulation strategy leads to significant reduction in dosages of both heparin and protamine. We can confidently move forward with investigating this anticoagulation concept. However, to establish clinical safety of ACT below 300 seconds, we need larger clinical studies.

Для цитирования: Bauer Adrian, Hausmann Harald, Schaarschmidt Jan, Szlapka Michal, Scharpenberg Martin, Eberle Thomas, Hasenkam J Michael. Is 300 Seconds ACT Safe and Efficient during MiECC Procedures?. The Thoracic and cardiovascular surgeon. 2017. DOI: 10.1055/s-0037-1609019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.