m+Medelevator.RU
← Поиск публикаций
Multiple sclerosis and related disorders · 2017

The validity and reliability of screening measures for depression and anxiety disorders in multiple sclerosis.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Marrie Ruth Ann, Zhang Lixia, Lix Lisa M, Graff Lesley A, Walker John R, Fisk John D, Patten Scott B, Hitchon Carol A, Bolton James M, Sareen Jitender, El-Gabalawy Renée, Marriott James J, Bernstein Charles N

Аннотация

OBJECTIVE: We aimed to evaluate the validity and reliability of multiple screening measures for depression and anxiety for use in the clinical care of people with multiple sclerosis (MS).

METHODS: Participants with MS completed the Patient Health Questionnaire (PHQ-9), Hospital Anxiety and Depression Scale (HADS), Kessler-6 Distress Scale, PROMIS Emotional Distress Depression Short-Form 8a (PROMIS Depression) and Anxiety Short-Form 8a (PROMIS Anxiety), Generalized Anxiety Disorder 7-item Scale (GAD-7), and the Overall Anxiety and Severity Impairment Scale (OASIS). A subgroup repeated the screening measures two weeks later. All participants also completed a Structured Clinical Interview for DSM-IV-TR Axis I Disorders (SCID). For the screening measures we computed sensitivity, specificity, positive predictive and negative predictive value with SCID diagnoses as the reference standard and conducted receiver operating curve (ROC) analyses; we also assessed internal consistency and test-retest reliability.

RESULTS: Of 253 participants, the SCID classified 10.3% with major depression and 14.6% with generalized anxiety disorder. Among the depression measures, the PHQ-9 had the highest sensitivity (84%). Specificity was generally higher than sensitivity, and was highest for the HADS-D with a cut-point of 11 (95%). In ROC analyses the area under the curve (AUC) did not differ between depression measures. Among the anxiety measures, sensitivity was highest for the HADS-A with a cut-point of 8 (82%). Specificity ranged from 83% to 86% for all measures except the HADS-A with a cut-point of 8 (68%). The AUC did not differ between anxiety measures.

CONCLUSION: Overall, performance of the depression and anxiety screening measures was very similar, with reasonable psychometric properties for the MS population, suggesting that other factors such as accessibility and ease of use could guide the choice of measure in clinical practice.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты