Correlation between serum magnesium and blood cyclosporine A concentrations in renal transplant recipients.
Аннотация
BACKGROUND
Low total serum magnesium concentration has been reported in renal transplant recipients on cyclosporine therapy, and this is a risk factor for hypertension and cardiac death. No study is yet available from the Indian subcontinent on the relationship between total serum magnesium and cyclosporine A concentration.
METHODS
Blood cyclosporine A and total serum magnesium concentrations were estimated in 31 post renal transplant patients. Sixteen chronic renal failure patients who had not yet received a transplant served as controls.
RESULTS
The mean total serum magnesium in post-transplant patients was 0.64+/-0.11 mmol/L (n = 31), which was significantly lower (P <0.001) than in the controls (1.0+/-0.16 mmol/L). An inverse correlation was found between total serum magnesium and blood cyclosporine A concentration (r = -0.532). Systolic and diastolic blood pressures were also higher in the cyclosporine-treated patients.
CONCLUSIONS
We conclude that serum magnesium should be monitored regularly in patients receiving cyclosporine A.