MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/c1cp20168a

Медицинская библиотека · Physical chemistry chemical physics : PCCP · 2011

Effect of air humidity on the removal of carbon tetrachloride from air using Cu-BTC metal-organic framework.

Martín-Calvo Ana, García-Pérez Elena, García-Sánchez Almudena, Bueno-Pérez Rocío, Hamad Said, Calero Sofia

СтатьяПеревод в очереди

Аннотация

We have used interatomic potential-based simulations to study the removal of carbon tetrachloride from air at 298 K, using Cu-BTC metal organic framework. We have developed new sets of Lennard-Jones parameters that accurately describe the vapour-liquid equilibrium curves of carbon tetrachloride and the main components from air (oxygen, nitrogen, and argon). Using these parameters we performed Monte Carlo simulations for the following systems: (a) single component adsorption of carbon tetrachloride, oxygen, nitrogen, and argon molecules, (b) binary Ar/CCl(4), O(2)/CCl(4), and N(2)/CCl(4) mixtures with bulk gas compositions 99 : 1 and 99.9 : 0.1, (c) ternary O(2)/N(2)/Ar mixtures with both, equimolar and 21 : 78 : 1 bulk gas composition, (d) quaternary mixture formed by 0.1% of CCl(4) pollutant, 20.979% O(2), 77.922% N(2), and 0.999% Ar, and (e) five-component mixtures corresponding to 0.1% of CCl(4) pollutant in air with relative humidity ranging from 0 to 100%. The carbon tetrachloride adsorption selectivity and the self-diffusivity and preferential sitting of the different molecules in the structure are studied for all the systems.

Для цитирования: Martín-Calvo Ana, García-Pérez Elena, García-Sánchez Almudena, Bueno-Pérez Rocío, Hamad Said, Calero Sofia. Effect of air humidity on the removal of carbon tetrachloride from air using Cu-BTC metal-organic framework.. Physical chemistry chemical physics : PCCP. 2011. DOI: 10.1039/c1cp20168a.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.