BACKGROUND

The technique of sentinel lymph node (SLN) biopsy in patients with breast cancer varies among reports, and the optimal method remains to be established, particularly with regard to the site of radiotracer injection. The aim of this study was to compare periareolar and peritumoral injection of radiotracer in detecting SLN in patients with breast cancer.

METHODS

Patients with T1-2 breast cancer (n = 155) were enrolled in this study. In phase 1 (n = 62), SLN biopsy was performed by using peritumoral injection of blue dye alone followed by backup axillary lymph node dissection. In phase 2, SLN biopsy was performed by using peritumoral injection of blue dye and peritumoral (group A, n = 41) or periareolar (group B, n = 52) injection of technetium 99m tin colloid.

RESULTS

In phase 1, the detection rate of SLN was 81% and the false-negative rate was 5.6%, indicating our skill in SLN biopsy. In phase 2, the success rate of lymphoscintigraphy was significantly (P <.001) higher in group B (90%) than in group A (51%). The mean ex vivo radioactivity of SLN in group B (117 counts per second; range, 5 to 900) was also significantly (P <.05) higher than in group A (51 counts per second; range, 8 to 260). In addition, the detection rate of SLN was significantly (P <.05) higher in group B (100%) than in group A (90%).

CONCLUSIONS

Periareolar injection of radiotracer for SLN biopsy is superior to peritumoral injection because of its simplicity, achieving a high success rate in lymphoscintigraphy and SLN detection.

Для цитирования: Shimazu Kenzo, Tamaki Yasuhiro, Taguchi Tetsuya, Takamura Yuuki, Noguchi Shinzaburo. Comparison between periareolar and peritumoral injection of radiotracer for sentinel lymph node biopsy in patients with breast cancer.. Surgery. 2002. DOI: 10.1067/msy.2002.121378.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.