MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jps.1066

Медицинская библиотека · Journal of pharmaceutical sciences · 2001

Tetracycline-selective electrode for content determination and dissolution studies of pharmaceuticals by flow-injection analysis (FIA).

Sales M G, Montenegro M C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The present work describes the construction and evaluation of different tetracycline (TC)-selective electrodes without inner reference solution and with polymer membranes. The several electrodes were prepared with poly(vinyl chloride) or ethylene(vinyl acetate) membranes comprising o-nitrophenyl octyl ether or bis(2-ethylhexyl)sebacate as mediator solvents and tetracycline tetrakis(4-clorophenyl)borate as ion exchanger. The best performance was recorded for the poly(vinyl chloride) membranes with bis(2-ethylhexyl)sebacate. Using solutions with adjusted ionic strength, this type of electrode presented a slope of 57.4 mV decade(-1) and a reproducibility of +/-0.3 mV day(-1), for an analytical range from 1.2 x 10(-4) to 1.0 x 10(-2) M. The pH working range was 2.0-3.8. Tubular-shaped potentiometric detectors based on the same selective membrane were also constructed. When TC solutions with adjusted ionic strength of concentrations ranging from 1.0 x 10(-4) to 1.0 x 10(-2) M were injected into a single-channel flow manifold, the detectors presented a slope of 56.6 mV decade(-1) and a reproducibility of +/-0.5 mV day(-1). The pH working range was 1.9-3.9. Both batch and flow procedures were applied to the potentiometric analysis of oral dosage forms. Average recoveries were within 98.6 to 100.3% and the t test indicated the accuracy of these results in comparison to an independent methodology. The flow system with the potentiometric detector was employed in dissolution studies as well.

Для цитирования: Sales M G, Montenegro M C. Tetracycline-selective electrode for content determination and dissolution studies of pharmaceuticals by flow-injection analysis (FIA).. Journal of pharmaceutical sciences. 2001. DOI: 10.1002/jps.1066.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.