MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.earlhumdev.2003.11.002

Медицинская библиотека · Early human development · 2004

Diastolic left ventricular function in preterm infants with a patent ductus arteriosus: a serial Doppler echocardiography study.

Schmitz Lothar, Stiller Brigitte, Koch Heike, Koehne Petra, Lange Peter

СтатьяПеревод в очереди

Аннотация

In very low birth weight neonates, a left-to-right shunt via persistent ductus arteriosus (PDA) may interact with diastolic left ventricular function, but specific changes of Doppler parameters have yet to be reported. In a serial transmitral Doppler study, we investigated the impact of a PDA on diastolic function parameters. Twenty-two patients with and without PDA were examined on day 3.8+/-1 and day 14+/-2 after birth. By the first examination, 13 out of 22 patients had a PDA; by the second examination, the number was still 8 out of 22. Peak early and atrial flow velocities (44.8+/-15 and 50.1+/-13 cm/s, respectively) were higher (p<0.05) for neonates with PDA compared to those with closed duct (30.9+/-6 and 34.2 cm/s, respectively). Isovolumic relaxation time (IVRT) was shorter in neonates with PDA (45+/-7 ms, N=21) compared to those with a closed duct (55.3+/-5 ms, N=23) (p<0.01). IVRT correlated inversely with cardiac index (R=-0.79, p<0.01). All observed changes reversed to the normal range after closure of the PDA. When premature infants with a PDA experience a preload challenge, early and atrial peak velocities increase and IVRT shortens significantly. This coincidence of elevated transvalvular pressure differences and decreased IVRT in neonates with immature diastolic function can best be explained as a result of left atrial pressure elevation. Consequently, pulmonary venous pressure must be elevated, with its inherent effect on pulmonary capillary physiology. Thus, the monitoring of left ventricular diastolic function adds significant information to the care of preterm infants with a PDA.

Для цитирования: Schmitz Lothar, Stiller Brigitte, Koch Heike, Koehne Petra, Lange Peter. Diastolic left ventricular function in preterm infants with a patent ductus arteriosus: a serial Doppler echocardiography study.. Early human development. 2004. DOI: 10.1016/j.earlhumdev.2003.11.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.