MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.3c01442

Медицинская библиотека · Analytical chemistry · 2023

Compartmentalized Linker Array: A Scalable and Transferrable Microarray Format for Multiplexed Immunoassays.

Aggarwal Roshan, Ferris Bryn, Li Huiyan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Microarrays have been widely used for multiplexed bioassays. Fabrication of a conventional microarray typically requires a complex microarray spotter, using which nanoliter bioreagent (e.g., antibody and cells) droplets are delivered onto a glass slide. However, arraying a delicate bioreagent in nanoliter volumes could cause the loss of bioactivity and needs a complex microarray spotter. Further, mixing of different bioreagents in a multiplexed assay leads to cross-reactions, producing false positive signals that impair assay reproducibility and scalability. In this work, we propose a new microarray format, named "compartmentalized linker array (CLA)", that consists of pre-prepared storable microarrays of chemical linkers in microliter compartments. CLA can be used for binding and patterning bioreagents into microarrays by simply pipetting and incubating bioreagent solutions in compartments. Using commonly used aminosilane linker-based antibody microarray, we developed CLA and demonstrated its application for a multiplexed sandwich immunoassay measuring three cancer-related proteins. A "two-phase" blocking system was established for de-activating background regions on glass where no linker molecules are present. Storage conditions of the CLA chip were explored and demonstrated for long-term storage. In a multiplexed immunoassay, low pg/mL sensitivity was achieved for all the three proteins, comparable to those of conventional assays. Moreover, CLA can be potentially used for other applications beyond protein assays, making microarray technology transferrable and widely available for the biological and biomedical research community.

Для цитирования: Aggarwal Roshan, Ferris Bryn, Li Huiyan. Compartmentalized Linker Array: A Scalable and Transferrable Microarray Format for Multiplexed Immunoassays.. Analytical chemistry. 2023. DOI: 10.1021/acs.analchem.3c01442.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.