Efficacy of Contact Lens Care Solutions in Removing Cholesterol Deposits From Silicone Hydrogel Contact Lenses.
Аннотация
PURPOSE: To determine the efficacy of multipurpose solutions (MPSs) on the removal of cholesterol deposits from silicone hydrogel (SH) contact lens materials using an in vitro model.
MATERIALS AND
METHODS
Five SH lens materials: senofilcon A, comfilcon A, balafilcon A, lotrafilcon A, and lotrafilcon B were removed from the blister pack (n=4 for each lens type), incubated for 7 days at 37°C in an artificial tear solution containing C radiolabeled cholesterol. Thereafter, lenses were stored in a preserved saline solution control (Sensitive Eyes Saline Plus) or cleaned with 1 of the 5 MPSs incorporating different preservatives (POLYQUAD/ALDOX, polyquaternium-1/alexidine, polyquaternium-1/PHMB, and 2 based on PHMB alone) using a rub and rinse technique, according to the manufacturer's recommendations, and stored in the MPS for a minimum of 6 hr. Lenses were then extracted with 2:1 chloroform:methanol, analyzed in a beta counter, and μg/lens of cholesterol was determined.
RESULTS
Balafilcon A and senofilcon A lens materials showed the highest amounts of accumulated cholesterol (0.93±0.02 μg/lens; 0.95±0.01 μg/lens, respectively), whereas lotrafilcon A and lotrafilcon B deposited the lowest amounts (0.37±0.03 μg/lens; 0.47±0.12 μg/lens, respectively). For all lens materials, the MPS preserved with POLYQUAD/ALDOX removed more deposited cholesterol than any other test solution; however, the amount of removed cholesterol contamination from the individual contact lenses was only statistically significant for balafilcon A and senofilcon A (P=0.006 and P=0.042, respectively). Sensitive eyes and the other evaluated MPSs showed no significant effect on cholesterol removal (P>0.05).
CONCLUSION
Cholesterol-removal efficacy varies depending on the combination of lens material and solution. Only 1 MPS showed a statistically significant reduction of cholesterol deposit for only 2 of the 5 tested lens materials.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.