DOI 10.1016/j.radonc.2025.110953

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2025

Daily proton dose re-calculation on deep-learning corrected cone-beam computed tomography scans.

Vestergaard Casper Dueholm, Muren Ludvig Paul, Elstrøm Ulrik Vindelev, Stolarczyk Liliana, Nørrevang Ole, Petersen Stine Elleberg, Taasti Vicki Trier

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Synthetic CT (sCT) generation from cone-beam CT (CBCT) must maintain stable performance and allow for accurate dose calculation across all treatment fractions to effectively support adaptive proton therapy. This study evaluated a 3D deep-learning (DL) network for sCT generation for prostate cancer patients over the full treatment course.

MATERIAL AND

METHODS

Patient data from 25/6 prostate cancer patients were used to train/test the DL network. Patients in the test set had a planning CT, 39 CBCT images, and at least one repeat CT (reCT) used for replanning. The generated sCT images were compared to fan-beam planning and reCT images in terms of i) CT number accuracy and stability within spherical regions-of-interest (ROIs) in the bladder, prostate, and femoral heads, ii) proton range calculation accuracy through single-spot plans, and iii) dose trends in target coverage over the treatment course (one patient).

RESULTS

The sCT images demonstrated image quality comparable to CT, while preserving the CBCT anatomy. The mean CT numbers on the sCT and CT images were comparable, e.g. for the prostate ROI they ranged from 29 HU to 59 HU for sCT, and from 36 HU to 50 HU for CT. The largest median proton range difference was 1.9 mm. Proton dose calculations showed excellent target coverage (V95%≥99.6%) for the high-dose target.

CONCLUSION

The DL network effectively generated high-quality sCT images with CT numbers, proton range, and dose characteristics comparable to fan-beam CT. Its robustness against intra-patient variations makes it a feasible tool for adaptive proton therapy.

Для цитирования: Vestergaard Casper Dueholm, Muren Ludvig Paul, Elstrøm Ulrik Vindelev, Stolarczyk Liliana, Nørrevang Ole, Petersen Stine Elleberg, Taasti Vicki Trier. Daily proton dose re-calculation on deep-learning corrected cone-beam computed tomography scans.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2025. DOI: 10.1016/j.radonc.2025.110953.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.