Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2020

Reproducibility of carotid sinus massage.

Brignole Michele, Croci Francesco, Solano Alberto, Donateo Paolo, Maggi Roberto, Solari Diana, Bertolone Cristina, Fontana Daniele, Oddone Daniele

СтатьяПеревод в очереди

Аннотация

AIMS: The reproducibility of carotid sinus massage (CSM) is debated. The aim of this study was to assess the reproducibility according to the methodology and diagnostic criteria defined by the guidelines on syncope of the European Society of Cardiology.

METHOD: Among 2800 patients with syncope who underwent CSM in the years 2005-2019, 109 patients (62 males; mean age 76 ± 10 years) had performed a second CSM after a median of 28 months. Carotid sinus hypersensitivity (CSH) was diagnosed when CSM elicited a pause of >3 s and/or a fall in systolic blood pressure >50 mm Hg without reproduction of spontaneous symptoms. Carotid sinus syndrome (CSS) was established when spontaneous symptoms were reproduced in the presence of bradycardia and/or hypotension.

RESULTS

The reproducibility of CSM was 78% for 18 CSS patients, 41% for 29 CSH patients, and 77% for 62 negative patients. The corresponding interrater agreement was good for CSS (kappa = 0.66), moderate for negative CSM (kappa = 0.42), and poor for CSH (kappa = 0.30). Combining CSH and negative tests, their reproducibility rose to 90% with kappa = 0.66.

CONCLUSION

CSS but not CSH has a good reproducibility. About half of patients with CSH had a negative response at the second test, thus suggesting a great overlap between them.

Для цитирования: Brignole Michele, Croci Francesco, Solano Alberto, Donateo Paolo, Maggi Roberto, Solari Diana, Bertolone Cristina, Fontana Daniele, Oddone Daniele. Reproducibility of carotid sinus massage.. Pacing and clinical electrophysiology : PACE. 2020. DOI: 10.1111/pace.13934.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.