MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3906/sag-1609-114

Медицинская библиотека · Turkish journal of medical sciences · 2017

Efficacy of bispectral index monitoring for prevention of anestheticawareness and complications during oocyte pick-up procedure.

Urfalıoğlu Aykut, Arslan Mahmut, Bakacak Murat, Öksüz Hafize, Boran Ömer Faruk, Öksüz Gözen

СтатьяПеревод в очереди

Аннотация

Background/aim: This study was planned by considering that the use of bispectral index (BIS) monitoring ensures sufficient depth of anesthesia and avoids anesthetic awareness and patient movement in the oocyte pick-up (OPU) procedure.Materials and methods: Ninety-eight patients undergoing OPU were randomly divided into 2 groups as the control group (n = 48) and BIS group (n = 50). After propofol and remifentanil induction, the control group was given additional propofol according to reaction response, while the BIS group was given propofol at BIS values of 60 and above with the aim that BIS values be 40?60. Total procedure time, recovery time, patient movement, additional propofol consumption, total number of oocytes, and awareness during anesthesia were recorded.

Results

Demographic data were similar in the two groups (P > 0.05 for all). The recovery time in the BIS group was significantly shorter compared to the control group (P < 0.001) while additional propofol consumption was found to be significantly lower (P < 0.001). Baseline BIS values fell compared to all other times after induction significantly (P < 0.001). No patient had anesthesia awareness.

Conclusion

During the OPU procedure BIS monitoring is considered to prevent anesthesia awareness, intraoperative movement, and complications caused by insufficient anesthetic use as it ensures optimal doses of anesthetic agents used and early recovery.

Для цитирования: Urfalıoğlu Aykut, Arslan Mahmut, Bakacak Murat, Öksüz Hafize, Boran Ömer Faruk, Öksüz Gözen. Efficacy of bispectral index monitoring for prevention of anestheticawareness and complications during oocyte pick-up procedure.. Turkish journal of medical sciences. 2017. DOI: 10.3906/sag-1609-114.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.