MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2016.12.005

Медицинская библиотека · European journal of radiology · 2016

Selection of peripheral intravenous catheters with 24-gauge side-holes versus those with 22-gauge end-hole for MDCT: A prospective randomized study.

Tamura Akio, Kato Kenichi, Kamata Masayoshi, Suzuki Tomohiro, Suzuki Michiko, Nakayama Manabu, Tomabechi Makiko, Nakasato Tatsuhiko, Ehara Shigeru

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

PURPOSE: To compare the 24-gauge side-holes catheter and conventional 22-gauge end-hole catheter in terms of safety, injection pressure, and contrast enhancement on multi-detector computed tomography (MDCT).

MATERIALS &

METHODS

In a randomized single-center study, 180 patients were randomized to either the 24-gauge side-holes catheter or the 22-gauge end-hole catheter groups. The primary endpoint was safety during intravenous administration of contrast material for MDCT, using a non-inferiority analysis (lower limit 95% CI greater than -10% non-inferiority margin for the group difference). The secondary endpoints were injection pressure and contrast enhancement.

RESULTS

A total of 174 patients were analyzed for safety during intravenous contrast material administration for MDCT. The overall extravasation rate was 1.1% (2/174 patients); 1 (1.2%) minor episode occurred in the 24-gauge side-holes catheter group and 1 (1.1%) in the 22-gauge end-hole catheter group (difference: 0.1%, 95% CI: -3.17% to 3.28%, non-inferiority P=1). The mean maximum pressure was higher with the 24-gauge side-holes catheter than with the 22-gauge end-hole catheter (8.16±0.95kg/cm2 vs. 4.79±0.63kg/cm2, P<0.001). The mean contrast enhancement of the abdominal aorta, celiac artery, superior mesenteric artery, and pancreatic parenchyma in the two groups were not significantly different.

CONCLUSION

In conclusion, our study showed that the 24-gauge side-holes catheter is safe and suitable for delivering iodine with a concentration of 300mg/mL at a flow-rate of 3mL/s, and it may contribute to the care of some patients, such as patients who have fragile and small veins. (Trial registration: UMIN000023727).

Для цитирования: Tamura Akio, Kato Kenichi, Kamata Masayoshi, Suzuki Tomohiro, Suzuki Michiko, Nakayama Manabu, Tomabechi Makiko, Nakasato Tatsuhiko, Ehara Shigeru. Selection of peripheral intravenous catheters with 24-gauge side-holes versus those with 22-gauge end-hole for MDCT: A prospective randomized study.. European journal of radiology. 2016. DOI: 10.1016/j.ejrad.2016.12.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.