OBJECTIVE

External electrical cardioversion is commonly used in the management of atrial fibrillation (AF), but usually involves general anaesthesia. We tested the efficacy, safety and tolerability of a minimally invasive cardioversion technique, not requiring general anaesthesia, performed on an outpatient basis.

METHODS

We performed outpatient oesophageal cardioversion in 87 consecutive patients (mean age: 67.5 +/- 9.6 years; weight: 77.47 +/- 12.34 kg; left atrium diameter: 46.25 +/- 6.85 mm; LVEF: 55.5 +/- 16%) with persistent AF (mean duration: 6.99 +/- 11.55 months). A biphasic shock was delivered via an oesophageal decapolar lead (cathode) and two precordial patches (anode) under a mild sedation (midazolam 2.5-5 mg). In the first 25 patients, a step-up protocol (from 10 to 100 J) was performed whereas, in the other 62, a first shock at 50 J and a second one at 100 J, were delivered.

RESULTS

Patients described the level of discomfort caused by the procedure according a five-grade scale. Cardioversion was achieved in 97.7% of patients using a mean effective energy of 51.2 +/- 15.7 J. In 88.5% of patients, sinus rhythm was restored by using 50 J or less. No complications occurred and no patient required hospital admission. Mean discomfort score was 1.56 +/- 0.74 out of 5. Sinus rhythm persisted in 62.6% of patients at the 1-month follow-up.

CONCLUSIONS

Outpatient oesophageal cardioversion is a safe, acceptable and effective way to cardiovert patients with AF. It may be a useful alternative to external cardioversion. A relatively high starting energy (50 J) was demonstrated to be superior to a low-energy step-up technique.

Для цитирования: Santini Luca, Magris Barbara, Topa Alessia, Gallagher Mark M, Forleo Giovanni B, Papavasileiou Lida P, Borzi Mauro, Romeo Francesco, Santini Massimo. Outpatient oesophageal-precordial electrical cardioversion of atrial fibrillation: an effective and safe technique to restore sinus rhythm.. Journal of cardiovascular medicine (Hagerstown, Md.). 2007. DOI: 10.2459/01.jcm.0000278440.74117.fe.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.