MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.jvca.2019.12.042

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2020

Preliminary Experience Using Diastolic Right Ventricular Pressure Gradient Monitoring in Cardiac Surgery.

Grønlykke Lars, Couture Etienne J, Haddad Francois, Amsallem Myriam, Ravn Hanne Berg, Raymond Meggie, Beaubien-Souligny William, Demers Philippe, Rochon Antoine, Sarabi Mahsa Elmi, Lamarche Yoan, Desjardins Georges, Denault André Y

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Right ventricular (RV) dysfunction in cardiac surgery is associated with increased mortality and morbidity and difficult separation from cardiopulmonary bypass (DSB). The primary objective of the present study was to describe the prevalence and characteristics of patients with abnormal RV diastolic pressure gradient (PG). The secondary objective was to explore the association among abnormal diastolic PG and DSB, postoperative complications, high central venous pressure (CVP), and high RV end-diastolic pressure (RVEDP).

DESIGN

Retrospective and prospective validation study.

SETTING

Tertiary care cardiac institute.

PARTICIPANTS

Cardiac surgical patients (n=374) from a retrospective analysis (n=259) and a prospective validation group (n=115).

INTERVENTION: RV pressure waveforms were obtained using a pulmonary artery catheter with a pacing port opened at 19 cm distal to the tip of the catheter. Abnormal RV diastolic PG was defined as >4 mmHg. Both elevated RVEDP and high CVP were defined as >16 mmHg.

MEASUREMENTS AND MAIN

RESULTS

From the retrospective and validation cohorts, 42.5% and 48% of the patients had abnormal RV diastolic PG before cardiac surgery, respectively. Abnormal RV diastolic PG before cardiac surgery was associated with higher EuroSCORE II (odds ratio 2.29 [1.10-4.80] v 1.62 [1.10-3.04]; p = 0.041), abnormal hepatic venous flow (45% v 29%; p = 0.038), higher body mass index (28.9 [25.5-32.5] v 27.0 [24.9-30.5]; p = 0.022), pulmonary hypertension (48% v 37%; p = 0.005), and more frequent DSB (32% v 19%; p = 0.023). However, RV diastolic PG was not an independent predictor of DSB, whereas RVEDP (odds ratio 1.67 [1.09-2.55]; p = 0.018) was independently associated with DSB. In addition, RV pressure monitoring indices were superior to CVP in predicting DSB.

CONCLUSION

Abnormal RV diastolic PG is common before cardiac surgery and is associated with a higher proportion of known preoperative risk factors. However, an abnormal RV diastolic PG gradient is not an independent predictor of DSB in contrast to RVEDP.

Для цитирования: Grønlykke Lars, Couture Etienne J, Haddad Francois, Amsallem Myriam, Ravn Hanne Berg, Raymond Meggie, Beaubien-Souligny William, Demers Philippe, Rochon Antoine, Sarabi Mahsa Elmi, Lamarche Yoan, Desjardins Georges, Denault André Y. Preliminary Experience Using Diastolic Right Ventricular Pressure Gradient Monitoring in Cardiac Surgery.. Journal of cardiothoracic and vascular anesthesia. 2020. DOI: 10.1053/j.jvca.2019.12.042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.