Clinical evaluation of AI software for rib fracture detection and its impact on junior radiologist performance.

Liu Xiang, Wu Dijia, Xie Huihui, Xu Yufeng, Liu Lin, Tao Xiaofeng, Wang Xiaoying

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The detection of rib fractures (RFs) on computed tomography (CT) images is time-consuming and susceptible to missed diagnosis. An automated artificial intelligence (AI) detection system may be helpful to improve the diagnostic efficiency for junior radiologists.

PURPOSE: To compare the diagnostic performance of junior radiologists with and without AI software for RF detection on chest CT images.

MATERIALS AND

METHODS

Six junior radiologists from three institutions interpreted 393 CT images of patients with acute chest trauma, with and without AI software. The CT images were randomly split into two sets at each institution, with each set assigned to a different radiologist First, the detection of all fractures (AFs), including displaced fractures (DFs), non-displaced fractures and buckle fractures, was analyzed. Next, the DFs were selected for analysis. The sensitivity and specificity of the radiologist-only and radiologist-AI groups at the patient level were set as primary endpoints, and secondary endpoints were at the rib and lesion level.

RESULTS

Regarding AFs, the sensitivity difference between the radiologist-AI group and the radiologist-only group were significant at different levels (patient-level: 26.20%; rib-level: 22.18%; lesion-level: 23.74%; P < 0.001). Regarding DFs, the sensitivity difference was 16.67%, 14.19%, and 16.16% at the patient, rib, and lesion levels, respectively (P < 0.001). No significant difference was found in the specificity between the two groups for AFs and DFs at the patient and rib levels (P > 0.05).

CONCLUSION

AI software improved the sensitivity of RF detection on CT images for junior radiologists and reduced the reading time by approximately 1 min per patient without decreasing the specificity.

Для цитирования: Liu Xiang, Wu Dijia, Xie Huihui, Xu Yufeng, Liu Lin, Tao Xiaofeng, Wang Xiaoying. Clinical evaluation of AI software for rib fracture detection and its impact on junior radiologist performance.. Acta radiologica (Stockholm, Sweden : 1987). 2021. DOI: 10.1177/02841851211043839.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.