MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archpedi.159.9.868

Медицинская библиотека · Archives of pediatrics & adolescent medicine · 2005

Pressure-regulated volume control ventilation vs synchronized intermittent mandatory ventilation for very low-birth-weight infants: a randomized controlled trial.

D'Angio Carl T, Chess Patricia R, Kovacs Stephen J, Sinkin Robert A, Phelps Dale L, Kendig James W, Myers Gary J, Reubens Linda, Ryan Rita M

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

OBJECTIVE

To test the hypothesis that pressure-regulated volume control (PRVC), an assist/control mode of ventilation, would increase the proportion of very low-birth-weight infants who were alive and extubated at 14 days of age as compared with synchronized intermittent mandatory ventilation (SIMV).

STUDY

DESIGN

Ventilated infants with birth weight of 500 to 1249 g were randomized at less than 6 hours of age either to pressure-limited SIMV or to PRVC on the Servo 300 ventilator (Siemens Electromedical Group, Danvers, Mass). Infants received their assigned mode of ventilation until extubation, death, or meeting predetermined failure criteria.

RESULTS

Mean +/- SD birth weights were similar in the SIMV (888 +/- 199 g, n = 108) and PRVC (884 +/- 203 g, n = 104) groups. No differences were detected between SIMV and PRVC groups in the proportion of infants alive and extubated at 14 days (41% vs 37%, respectively), length of mechanical ventilation in survivors (median, 24 days vs 33 days, respectively), or the proportion of infants alive without a supplemental oxygen requirement at 36 weeks' postmenstrual age (57% vs 63%, respectively). More infants receiving SIMV (33%) failed their assigned ventilator mode than did infants receiving PRVC (20%). Including failure as an adverse outcome did not alter the overall outcome (39% of infants in the SIMV group vs 35% of infants in the PRVC group were alive, extubated, and had not failed at 14 days).

CONCLUSION

In mechanically ventilated infants with birth weights of 500 to 1249 g, using PRVC ventilation from birth did not alter time to extubation.

Для цитирования: D'Angio Carl T, Chess Patricia R, Kovacs Stephen J, Sinkin Robert A, Phelps Dale L, Kendig James W, Myers Gary J, Reubens Linda, Ryan Rita M. Pressure-regulated volume control ventilation vs synchronized intermittent mandatory ventilation for very low-birth-weight infants: a randomized controlled trial.. Archives of pediatrics & adolescent medicine. 2005. DOI: 10.1001/archpedi.159.9.868.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.