MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/euhj.2001.3154

Медицинская библиотека · European heart journal · 2002

Efficacy of a dual chamber defibrillator with atrial antitachycardia functions in treating spontaneous atrial tachyarrhythmias in patients with life-threatening ventricular tachyarrhythmias.

Ricci R, Pignalberi C, Disertori M, Capucci A, Padeletti L, Botto G, Toscano S, Miraglia F, Grammatico A, Santini M

Клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Atrial fibrillation has a high incidence in patients wearing an implantable cardioverter defibrillator for ventricular tachyarrhythmias and may lead to palpitations, heart failure, angina, stroke and inappropriate defibrillator discharge. The aim of the study was to evaluate the efficacy of a dual chamber defibrillator with atrial antitachycardia functions in treating spontaneous atrial tachyarrhythmias.

METHODS

One hundred and twelve patients, 88 male, mean age 64+/-11 years, were enrolled. Seventy-six had ischaemic heart disease, 21 idiopathic dilated cardiomyopathy, nine other heart diseases, six no structural heart disease. The mean left ventricular ejection fraction was 40+/-11%. Sixty-two had prior atrial tachyarrhythmias.

RESULTS

Follow-up lasted 11+/-9 months (range 1-42). Among 933 ventricular tachyarrhythmia episodes, 100% of ventricular fibrillation and 92% of ventricular tachycardia were successfully cardioverted. Among 414 detected sustained atrial tachyarrhythmias, 195 were classified as atrial tachycardia (47.1%), 192 as atrial fibrillation (46.4%) and 27 (6.5%) as sinus rhythm. The detection-positive predictive value was 93.5%. Therapy success rates: antitachy pacing on atrial tachycardia = 71.3% (crude estimate); 66.1% (adjusted estimate); 50 Hertz on atrial fibrillation=36.2% (crude estimate); 13.5% (adjusted estimate); atrial shock on atrial fibrillation = 62.5% (mean energy 7.8+/-14.1J). Shock efficacy was 32% when delivered energy was < or = 2 atrial defibrillation threshold at implant and 92% when >2. Duration of successfully treated atrial episodes was significantly lower than that of unsuccessfully treated (6+/-26 min vs 42+/-60).

CONCLUSIONS

Atrial antitachy pacing and shock therapies demonstrated very high efficacy in treating atrial tachyarrhythmias in defibrillator patients.

Для цитирования: Ricci R, Pignalberi C, Disertori M, Capucci A, Padeletti L, Botto G, Toscano S, Miraglia F, Grammatico A, Santini M. Efficacy of a dual chamber defibrillator with atrial antitachycardia functions in treating spontaneous atrial tachyarrhythmias in patients with life-threatening ventricular tachyarrhythmias.. European heart journal. 2002. DOI: 10.1053/euhj.2001.3154.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.