MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5489/cuaj.8113

Медицинская библиотека · Canadian Urological Association journal = Journal de l'Association des urologues du Canada · 2023

Use of timed alarm device for pediatric daytime urinary incontinence Meta-analysis of comparative studies.

Chua Michael E, Rickard Mandy, Kim Jin Kyu, Brownrigg Natasha, Dos Santos Joana, Aba Luzelle Kate, Lorenzo Armando, Mistry Niraj

СтатьяОбзорПеревод в очереди

Аннотация

INTRODUCTION

This meta-analysis aimed to determine the comparative effectiveness of timed alarm device-assisted urotherapy vs. standard urotherapy alone in managing pediatric daytime urinary incontinence (pDUI).

METHODS

A systematic literature search was performed in December 2021, with an update search in July 2022. Comparative studies assessing the pDUI treatment effectiveness of timed alarm device-assisted urotherapy vs. urotherapy alone were identified and evaluated according to Cochrane collaboration recommendations. The assessed outcome includes pDUI complete response and adherence rates. Relative risk (RR ) with 95% confidence intervals (CI) was extrapolated. A random-effects model was used to pool effect estimates. Heterogeneity was assessed with sensitivity and subgroup analysis performed according to study design and comparative group characteristics. GRADE criteria were used to assess evidence certainty. (PROSPEROCRD 42022299173).

RESULTS

Four studies (three randomized controlled trials [RCTs] and one retrospective cohort) with 635 cases were included. The pooled effect estimates of pDUI complete response showed no differences between intervention groups (RR 1.20, 95% CI 0.81, 1.76). Pooled effect estimates for treatment adherence were generated from two studies, which showed significantly better adherence for the timed-alarm device group (RR 2.97, 95% CI 1.46, 6.06). Significant interstudy heterogeneity was noted; the source is likely from the study design and comparator device characteristics. The quality of evidence was assessed to be of very low certainty.

CONCLUSIONS

Based on very low certainty evidence, timed alarm device-assisted urotherapy does not seem to have the advantage of complete treatment response over standard urotherapy alone in managing pDUI; however, a timed-alarm device is likely able to improve urotherapy treatment adherence.

Для цитирования: Chua Michael E, Rickard Mandy, Kim Jin Kyu, Brownrigg Natasha, Dos Santos Joana, Aba Luzelle Kate, Lorenzo Armando, Mistry Niraj. Use of timed alarm device for pediatric daytime urinary incontinence Meta-analysis of comparative studies.. Canadian Urological Association journal = Journal de l'Association des urologues du Canada. 2023. DOI: 10.5489/cuaj.8113.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.